Accurate measurement of uranium isotope ratios in solid samples by laser ablation multi-collector inductively coupled plasma mass spectrometry

Abstract: A multi-collector inductively coupled plasma mass spectrometer (MC-ICP-MS) coupled to a 213 nm ns-laser was used to measure uranium isotope ratios (234U/238U, 235U/238U, and 236U/238U) in six solid nuclear certified reference materials (CRMs).

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

0
23
0

Year Published

2019
2019
2024
2024

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 20 publications
(23 citation statements)
references
References 17 publications
0
23
0
Order By: Relevance
“…To overcome the above mentioned drawbacks, laser ablation (LA), coupled to either single or multi-collector ICP-MS, is increasingly employed for U isotopic analysis of nuclear samples [ [10] , [11] , [12] , [13] , [14] , [15] , [16] , [17] , [18] , [19] , [20] ]. As LA does not require any sophisticated sample preparation, measurement results can be obtained in a timely manner.…”
Section: Introductionmentioning
confidence: 99%
“…To overcome the above mentioned drawbacks, laser ablation (LA), coupled to either single or multi-collector ICP-MS, is increasingly employed for U isotopic analysis of nuclear samples [ [10] , [11] , [12] , [13] , [14] , [15] , [16] , [17] , [18] , [19] , [20] ]. As LA does not require any sophisticated sample preparation, measurement results can be obtained in a timely manner.…”
Section: Introductionmentioning
confidence: 99%
“…At such low uences, uctuations may be expected that are liable to have an essential impact on the laser ablation rate. 8 Compared to our previous work, [10][11][12] the carrier gas of the LA unit was changed from Ar to He in this study. The use of He instead of Ar is known to change the aerosol expansion and to improve the transport efficiency.…”
Section: Resultsmentioning
confidence: 98%
“…Further experimental details were reported earlier. [10][11][12] The Faraday detectors of a double-focusing multi-collector inductively coupled plasma mass spectrometer (MC-ICP-MS, Nu Plasma™, NU Instruments, Wrexham, Wales, U.K.) measured the abundance of 235 U and 238 U in the ablated particle cloud. Before switching to LA, the MC-ICP-MS was tuned for sensitivity and stability of U signals in solution mode employing an aqueous 30 ng L À1 U calibration solution having natural U isotopic composition.…”
Section: Instrumentationmentioning
confidence: 99%
See 2 more Smart Citations