2016
DOI: 10.1002/2016jd025531
|View full text |Cite
|
Sign up to set email alerts
|

Accurate laboratory determination of the near‐infrared water vapor self‐continuum: A test of the MT_CKD model

Abstract: The semi‐empirical MT_CKD model of the absorption continuum of water vapor is widely used in atmospheric radiative transfer codes of the atmosphere of Earth and, recently, of exoplanets but lacks of experimental validation in the atmospheric windows. Recent laboratory measurements by Fourier transform Spectroscopy led to self‐continuum cross sections much larger than the MT_CKD values in the near‐infrared transparency windows. We report on accurate measurements by Cavity Ring Down Spectroscopy (CRDS) and Optic… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
2
1

Citation Types

1
28
0

Year Published

2017
2017
2022
2022

Publication Types

Select...
5
1
1

Relationship

1
6

Authors

Journals

citations
Cited by 35 publications
(33 citation statements)
references
References 68 publications
1
28
0
Order By: Relevance
“…More recently, we have implemented highly sensitive cavity enhanced laser techniques at different spectral points of the 4.0, 2.1, 1.6 and 1.25 µm windows to measure in the laboratory the self-continuum absorption of water vapour Campargue et al, 2016;Ventrillard et al, 2015;Richard et al, 2017). Overall, these measurements by Optical Feedback Cavity Enhanced Absorption Spectroscopy (OFCEAS) and Cavity Ring-down Spectroscopy (CRDS) were found closer to the MT_CKD model than to the FTS results.…”
Section: Introductionmentioning
confidence: 74%
See 1 more Smart Citation
“…More recently, we have implemented highly sensitive cavity enhanced laser techniques at different spectral points of the 4.0, 2.1, 1.6 and 1.25 µm windows to measure in the laboratory the self-continuum absorption of water vapour Campargue et al, 2016;Ventrillard et al, 2015;Richard et al, 2017). Overall, these measurements by Optical Feedback Cavity Enhanced Absorption Spectroscopy (OFCEAS) and Cavity Ring-down Spectroscopy (CRDS) were found closer to the MT_CKD model than to the FTS results.…”
Section: Introductionmentioning
confidence: 74%
“…The strong disagreement with FTS measurements (Ptashnik et al, 2011a(Ptashnik et al, , 2013(Ptashnik et al, , 2015 has been discussed by Shine et al (2016) and Campargue et al (2016). The measurement of a very small variation of a FTS spectrum baseline induced by the injection of water vapour in an absorption cell requires high baseline stability during the entire measurement period.…”
Section: Resultsmentioning
confidence: 99%
“…As illustrated in Fig. 6 The strong disagreement with FTS measurements (Ptashnik et al, 2011a(Ptashnik et al, , 2013(Ptashnik et al, , 2015 has been discussed by Shine et al, 2016 andCampargue et al 2016. The measurement of a very small variation of a FTS spectrum baseline induced by the injection of water vapor in an absorption cell requires very high baseline stability during the entire measurement period.…”
Section: Resultsmentioning
confidence: 98%
“…More recently, we have implemented highly sensitive cavity enhanced laser techniques at different spectral points of the 4.0, 2.1, 1.6 and 1.25 µm to measure in the laboratory the self-continuum absorption of water vapor (Mondelain et al 2013;2014Campargue et al 2016;Ventrillard et al 2015;Richard et al 2017). Overall, these measurements by Optical Feedback Cavity Enhanced Absorption Spectroscopy (OFCEAS) and Cavity Ring-down Spectroscopy (CRDS) were found closer to the MT_CKD model than to the FTS results.…”
Section: Introductionmentioning
confidence: 83%
See 1 more Smart Citation