2002
DOI: 10.1016/s0009-8981(02)00178-x
|View full text |Cite
|
Sign up to set email alerts
|

Accurate direct spectrophotometric bilirubin measurement combined with blood gas analysis

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
9
0
1

Year Published

2006
2006
2021
2021

Publication Types

Select...
7
1
1

Relationship

0
9

Authors

Journals

citations
Cited by 17 publications
(10 citation statements)
references
References 6 publications
0
9
0
1
Order By: Relevance
“…However, the accuracy of TSB measurement in our unit by reflectance spectrophotometry (GB 13/A TM Bilirubinometer, Bertocchi SRL Elettromedicali, Italy) was recently tested, and the correlation between our laboratory method and the HPLC method was high (r = 0.927; 95% CI = 0.906-0.944) [6] . Moreover, some reports have shown that the new multi-wavelength spectrophotometric method developed by Radiometer measures TSB concentrations accurately and precisely in conjunction with blood gas analysis/co-oximetry (ABL 735 TM ) [15,16] .…”
Section: Discussionmentioning
confidence: 99%
“…However, the accuracy of TSB measurement in our unit by reflectance spectrophotometry (GB 13/A TM Bilirubinometer, Bertocchi SRL Elettromedicali, Italy) was recently tested, and the correlation between our laboratory method and the HPLC method was high (r = 0.927; 95% CI = 0.906-0.944) [6] . Moreover, some reports have shown that the new multi-wavelength spectrophotometric method developed by Radiometer measures TSB concentrations accurately and precisely in conjunction with blood gas analysis/co-oximetry (ABL 735 TM ) [15,16] .…”
Section: Discussionmentioning
confidence: 99%
“…57 A range of more quantitative techniques based on derivate spectrophotometry have been described. [58][59][60] These techniques may be relevant for determining the longitudinal profile of CSF bilirubin as proposed above.…”
Section: The Uk Experiencementioning
confidence: 99%
“…Some validation studies using neonatal whole blood samples provided conflicting correlations between blood gas analyzers and chemistry analyzers [ [5] , [6] , [7] , [8] , [9] ], which confused physicians in interpreting whole blood bilirubin results for patient management. The common causes of bias are a lack of standardized plasma bilirubin reference methods [ 10 , 11 ] and the difference in methodologies between blood gas analyzers using multiple-wavelength photometry and chemistry analyzers using diazo based assay [ [5] , [6] , [7] , [8] , [9] ].…”
Section: Introductionmentioning
confidence: 99%