2003
DOI: 10.1016/s1090-7807(03)00113-7
|View full text |Cite
|
Sign up to set email alerts
|

Accurate determination of small one-bond heteronuclear residual dipolar couplings by F1 coupled HSQC modified with a G-BIRD(r) module

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
40
0
2

Year Published

2006
2006
2018
2018

Publication Types

Select...
9
1

Relationship

3
7

Authors

Journals

citations
Cited by 56 publications
(43 citation statements)
references
References 23 publications
1
40
0
2
Order By: Relevance
“…For monitoring the temperature dependence of the liquid crystalline system, a 15 min equilibration period was interleaved between successive temperatures. The 1 H, 13 C couplings ( 1 T CH = 1 J CH + 1 D CH ) [22] for 1 were measured from HSQC spectra with no decoupling in the 13 C dimension using a new pulse scheme including a BIRD filter within the HSQC sequence [23] at the same instrument using a TBI probe. The measurements for 2 were performed on a Bruker DRX-600 instrument equipped with a 5 mm TBI probe.…”
Section: Methodsmentioning
confidence: 99%
“…For monitoring the temperature dependence of the liquid crystalline system, a 15 min equilibration period was interleaved between successive temperatures. The 1 H, 13 C couplings ( 1 T CH = 1 J CH + 1 D CH ) [22] for 1 were measured from HSQC spectra with no decoupling in the 13 C dimension using a new pulse scheme including a BIRD filter within the HSQC sequence [23] at the same instrument using a TBI probe. The measurements for 2 were performed on a Bruker DRX-600 instrument equipped with a 5 mm TBI probe.…”
Section: Methodsmentioning
confidence: 99%
“…The F 1 -coupled HSQC is another alternative wherein the advantage of homonuclear decoupling has been derived by the insertion of G-BIRD(r) module in the middle of F 1 dimension. This demands a longer experimental time as many t 1 -increments are required to achieve high resolution in the F 1 -dimension [31]. This disadvantage has been partially overcome by utilizing the J-resolved type of experiments, such as, J-resolved HMQC and J-resolved HSQC [32,33].…”
Section: Measurement Of Homo-and Hetero-nuclear Rdcsmentioning
confidence: 99%
“…To achieve a similar effect here, we use modified BIRD pulses [25]. Such pulses have been used previously to remove unwanted interaction from the indirectly detected dimensions of 2D experiments [32,33]. The modified BIRD pulse applied in the middle of the t 1 period eliminates evolution of proton-proton couplings that would otherwise accelerate signal decay.…”
Section: D J-ha(caco)nh and 2d (J-hacaco)nhmentioning