2015
DOI: 10.1016/j.jmu.2014.10.006
|View full text |Cite
|
Sign up to set email alerts
|

Accurate Detection of Retained Products of Conception after First- and Second-trimester Abortion by Color Doppler Sonography

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

1
11
0

Year Published

2015
2015
2024
2024

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 14 publications
(12 citation statements)
references
References 17 publications
1
11
0
Order By: Relevance
“…Using histopathology as confirmatory test, the overall sensitivity of TVS for diagnosis of RPOC in present study is 92% which is comparable to study conducted by De Vries et al, Matijevic et al and Esmaeillou et al [11][12][13] The overall specificity of TVS is 60%, which is comparable to that in study conducted by Esmaeillou et al, higher than in study conducted by Matijevic et but lower than other studies. 12,13 This is because of relatively high number of false positive results which might be due to false interpretation of blood clot for RPOC which also looks like echogenic mass on ultrasound or presence of thickened endometrium giving impression of RPOC but proved to be thickened decidua with absence of chorionic villi on histopathology.…”
Section: Discussionsupporting
confidence: 76%
See 1 more Smart Citation
“…Using histopathology as confirmatory test, the overall sensitivity of TVS for diagnosis of RPOC in present study is 92% which is comparable to study conducted by De Vries et al, Matijevic et al and Esmaeillou et al [11][12][13] The overall specificity of TVS is 60%, which is comparable to that in study conducted by Esmaeillou et al, higher than in study conducted by Matijevic et but lower than other studies. 12,13 This is because of relatively high number of false positive results which might be due to false interpretation of blood clot for RPOC which also looks like echogenic mass on ultrasound or presence of thickened endometrium giving impression of RPOC but proved to be thickened decidua with absence of chorionic villi on histopathology.…”
Section: Discussionsupporting
confidence: 76%
“…12,13 This is because of relatively high number of false positive results which might be due to false interpretation of blood clot for RPOC which also looks like echogenic mass on ultrasound or presence of thickened endometrium giving impression of RPOC but proved to be thickened decidua with absence of chorionic villi on histopathology.…”
Section: Discussionmentioning
confidence: 99%
“…Detecting RPOC with transvaginal ultrasound is a noninvasive assessment tool before medical or surgical treatments. [ 1 ] Several kinds of sonographic features of RPOC were reported, such as endometrial mass, greater endometrial thickness (ET), and high endometrial vascularity.…”
Section: Discussionmentioning
confidence: 99%
“…Esmaeillou et al . compared the diagnostic performance of ET ≥10 mm, vascular pattern, and endometrial echogenic mass;[ 1 ] they found that combination of endometrial vascularity and hyperechoic mass is the best predictor of RPOC, with 88% sensitivity, 89% specificity, 85% positive predictive value, and 93% negative predictive value. They also found that ET ≥10 mm is a doubtful parameter in detecting RPOC, because 52% patients with ET ≥10 mm had no RPOC, in other words a high false-positive rate.…”
Section: Discussionmentioning
confidence: 99%
“…Each measurement was taken twice with a 5-min interval and the average values were used in analysis. A transvaginal color Doppler ultrasound has been shown to have a 88% sensitivity and 68% specificity in diagnosis of RPOC [29]. Furthermore, the decreased measures of AP-diameter of RPOC has been shown to be an indicator of complete spontaneous resolution [30].…”
Section: Outcome Measurementsmentioning
confidence: 99%