2022
DOI: 10.37934/arfmts.93.1.123135
|View full text |Cite
|
Sign up to set email alerts
|

Accurate Assessment Model for Solving Resistance-Temperature Equations of Platinum Thermometers in Range from -40 °C up to 660 °C

Abstract: The missions of the thermal metrology laboratory are to maintain, disseminate, develop and realize the International Temperature Scale 1990 (ITS-90). One of the services that the laboratory has introduced is the routine calibration to all industrial sectors that covers almost all fields inside and outside Egypt. This work compares different interpolating equations of set of industrial Platinum Resistance Thermometers (IPRTs) in the temperature range from -40 °C up to 660 °C that convert the resistance of therm… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1

Citation Types

0
1
0

Year Published

2022
2022
2022
2022

Publication Types

Select...
1

Relationship

0
1

Authors

Journals

citations
Cited by 1 publication
(1 citation statement)
references
References 0 publications
0
1
0
Order By: Relevance
“…Our mission is to maintain, disseminate and develop the unit of thermodynamic temperature that was defined by the Boltzmann constant in the advanced research branch and the approximated thermodynamic temperature that was realized by the International Temperature Scale 1990 (ITS-90). Furthermore, there are another mission for ThML is to introduce the industrial routine calibration, thermal exposure, viscosity, humidity, thermal conductivity, and more services that are traceable to ITS-90 [1][2][3][4][5][6][7][8]. Thermal conductivity is a physical quantity that must be taken into consideration when evaluating building materials, as it is one of the most important requirements, especially in extreme areas in high or low temperatures in a thermal climate.…”
Section: Introductionmentioning
confidence: 99%
“…Our mission is to maintain, disseminate and develop the unit of thermodynamic temperature that was defined by the Boltzmann constant in the advanced research branch and the approximated thermodynamic temperature that was realized by the International Temperature Scale 1990 (ITS-90). Furthermore, there are another mission for ThML is to introduce the industrial routine calibration, thermal exposure, viscosity, humidity, thermal conductivity, and more services that are traceable to ITS-90 [1][2][3][4][5][6][7][8]. Thermal conductivity is a physical quantity that must be taken into consideration when evaluating building materials, as it is one of the most important requirements, especially in extreme areas in high or low temperatures in a thermal climate.…”
Section: Introductionmentioning
confidence: 99%