2021
DOI: 10.1016/j.jpba.2021.114066
|View full text |Cite
|
Sign up to set email alerts
|

Accurate and reliable quantitation of short chain fatty acids from human feces by ultra high-performance liquid chromatography-high resolution mass spectrometry (UPLC-HRMS)

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
9
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
8
1

Relationship

1
8

Authors

Journals

citations
Cited by 22 publications
(10 citation statements)
references
References 48 publications
1
9
0
Order By: Relevance
“…Excellent chromatographic resolution and characteristic fragments of DMED/DEEA-SCFAs derivatives were also simultaneously achieved. These enhanced signals further improved the assay validity of the method with lower LOD, LOQ, and a better linear range as previously described ( 21 , 22 , 23 , 24 ).…”
Section: Resultssupporting
confidence: 65%
“…Excellent chromatographic resolution and characteristic fragments of DMED/DEEA-SCFAs derivatives were also simultaneously achieved. These enhanced signals further improved the assay validity of the method with lower LOD, LOQ, and a better linear range as previously described ( 21 , 22 , 23 , 24 ).…”
Section: Resultssupporting
confidence: 65%
“…This DNA was submitted for 16 S rRNA gene sequencing which will be reported in future studies. In addition, SCFA analysis were conducted on 40 samples, the results of which are reported previously [ 30 ].…”
Section: Resultsmentioning
confidence: 99%
“…A Thermo Scientific Vanquish Flex UPLC coupled Q Exactive (QE) system was used to analyze derivatized SCFAs. According to the FDA guideline for bioanalytical method validation [28], the calibration curve, accuracy, precision, recovery and stability of targeted SCFAs were validated as described in our earlier study [29].…”
Section: Stool Short Chain Fatty Acid Detection and Validation Analysismentioning
confidence: 99%
“…Different HPLC technologies have been used over years to quantify SCFAs [25,29,30], especially in studies where the intestinal microbiota was altered in association with various pathological conditions [31][32][33][34][35]. In our study, coupling tandem mass spectrometry to HPLC (HPLC-MS-MS) to quantify acetic, propionic, and butyric acids in microbial culture supernatants led to a very speci c and sensitive detection, which is properly required when low analyte concentrations are present, as in the case of SCFAs [36,37].…”
Section: Discussionmentioning
confidence: 99%