Abstract:High-quality
oxygen isotope analysis of composition-variable minerals
(e.g., ubiquitous carbonates) using secondary ion mass spectrometry
(SIMS) is extremely challenging. The classical off-line procedure,
which requires additional electron probe microanalyzer (EPMA) chemical
compositions for calibrating instrumental mass fractionation (IMF),
is inherently inaccurate and analytically inefficient. In this study,
the first accurate and paired SIMS analysis of δ18O and Fe# [molar Fe/(Mg + Fe)] in dolomite is repor… Show more
“…One of the important issues that affect the accuracy of microbeam analysis is the matrix effect. [66][67][68][69][70] In this case systematical assessment of the matrix effect was conducted by using PZH12-15 ilmenite, the most homogeneous natural mineral assessed on a 35 mm-scale and precision of the measurement in this study, as the bracketing reference material to analyze the other ilmenites, rutiles and Alfa-Ti metal. The results are summarized in Table 3 and illustrated in Fig.…”
Section: Matrix Effect Of Fs-la-mc-icp-ms Ti Isotopic Analysismentioning
Titanium (Ti) isotopes are emerging as a power tool for studying magmatic processes on the Earth and other planets. Pioneering studies carried out bulk-rock Ti isotopic measurements by conventional solution...
“…One of the important issues that affect the accuracy of microbeam analysis is the matrix effect. [66][67][68][69][70] In this case systematical assessment of the matrix effect was conducted by using PZH12-15 ilmenite, the most homogeneous natural mineral assessed on a 35 mm-scale and precision of the measurement in this study, as the bracketing reference material to analyze the other ilmenites, rutiles and Alfa-Ti metal. The results are summarized in Table 3 and illustrated in Fig.…”
Section: Matrix Effect Of Fs-la-mc-icp-ms Ti Isotopic Analysismentioning
Titanium (Ti) isotopes are emerging as a power tool for studying magmatic processes on the Earth and other planets. Pioneering studies carried out bulk-rock Ti isotopic measurements by conventional solution...
“…Certied U particles were used 26 in a comparison of AMS, SIMS and TIMS for the determination of isotope ratios in individual U particles, an application important for nuclear provenance and safeguarding purposes. The relative errors in the determination of 234 U/ 235 U and 234 U/ 236 U in NBL CRM U200 (uranium isotopic standard) by AMS were <10 and <20%, respectively, whereas the results obtained by ssion track-TIMS and SIMS were within ±5% and ±10% of the certied values, respectively, for both techniques. The relative error and external precision of 234 U/ 238 U and 235 U/ 238 U in the analysis of NBL CRM U850 (uranium (U 3 O 8 ) isotopic standard, 85% U-235) by AMS, SEM-TIMS or SIMS were <10% and <5%, respectively.…”
Section: Reference Materials and Instrumental Intercomparisonsmentioning
confidence: 80%
“…The relative errors in the determination of 234 U/ 235 U and 234 U/ 236 U in NBL CRM U200 (uranium isotopic standard) by AMS were <10 and <20%, respectively, whereas the results obtained by ssion track-TIMS and SIMS were within ±5% and ±10% of the certied values, respectively, for both techniques. The relative error and external precision of 234 U/ 238 U and 235 U/ 238 U in the analysis of NBL CRM U850 (uranium (U 3 O 8 ) isotopic standard, 85% U-235) by AMS, SEM-TIMS or SIMS were <10% and <5%, respectively. The average values of the relative error and external precision for 236 U/ 238 U were both <5% for AMS analysis but <10% for SEM-TIMS or SIMS analyses.…”
Section: Reference Materials and Instrumental Intercomparisonsmentioning
confidence: 80%
“…A new suite of olivine and pyroxene RMs with an expanded range of compositions was developed to provide better analytical precision and instrumental bias correction in the analysis of olivine and low-Ca pyroxene in primitive chondrule minerals. A novel method for the determination of d 18 O and molar ratio Fe/(Mg + Fe) (known as Fe#) in dolomite by SIMS involved 235 the concurrent measurement of 18 O 16 O, 56 Fe 16 O and 24 Mg 16 O, thereby avoiding the need for additional EPMA compositional information. Five newly developed dolomite RMs with an Fe# range of 0.01 to 0.35 were employed for calibration.…”
This review covers advances in the analysis of air, water, plants, soils and geological materials by a range of atomic spectrometric techniques including atomic emission, absorption, fluorescence and mass spectrometry.
“…"Offline" methods to calibrate the matrix effect are commonly used, by which the quantitative determination of SiO 2 contents using EMPA in unknown samples is required to estimate IMF subsequently based on empirical correction curves. 24,25,29,33,34,76,77 Here, we compare the IMF-correction efficacy of the up-to-date "online" method with that of the conventional "offline" method.…”
Section: Effects Of Chemical Compositions On Imfmentioning
NanoSIMS Li isotope analysis of silicate glasses is affected by instrumental mass fractionation (IMF) due to the matrix effect. Here, we found that the IMF is correlated with the silica content and can be well corrected.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.