2013
DOI: 10.1016/j.ijleo.2012.10.057
|View full text |Cite
|
Sign up to set email alerts
|

Accurate and efficient algorithm for simulation of fringe projection system

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
5
0

Year Published

2017
2017
2023
2023

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(5 citation statements)
references
References 15 publications
0
5
0
Order By: Relevance
“…Comparing the calculated height with the preset value, we obtain the error distribution, (figure 7(b)). The profile of the height error along the middle row (figure 7(c)) shows that the error values are basically below the preset iteration threshold value of 0.005 mm, which exceeds that of existing methods [6][7][8][9]. But at the edge area where the gradient is not continuous, the iteration will not converge to the preset value to cause larger error.…”
Section: Iterative Precision Verificationmentioning
confidence: 86%
See 3 more Smart Citations
“…Comparing the calculated height with the preset value, we obtain the error distribution, (figure 7(b)). The profile of the height error along the middle row (figure 7(c)) shows that the error values are basically below the preset iteration threshold value of 0.005 mm, which exceeds that of existing methods [6][7][8][9]. But at the edge area where the gradient is not continuous, the iteration will not converge to the preset value to cause larger error.…”
Section: Iterative Precision Verificationmentioning
confidence: 86%
“…Duo Zhou 1 , Zhangying Wang 1 , Nan Gao 1 , Zonghua Zhang 1,2 and Xiangqian Jiang 2 expression relating phase to height is derived. In most explicit calibration methods [1][2][3][4][5][6][7][8][9][10][11][12][13], the system configuration should meet the following three conditions: (a) the optical centres of the camera and projector must be set parallel to the reference plane; (b) the optical axis of the camera must be perpendicular to the reference plane; and (c) the optical axes of the camera and projector must be coplanar and their intersection point is on the reference plane. However, actual systems are seldom set up in accordance with these conditions, and a universal calibration method therefore is needed.…”
Section: Virtual Fringe Projection System With Nonparallel Illuminati...mentioning
confidence: 99%
See 2 more Smart Citations
“…Yingchun et al [11] proposed an FPP simulation system based on inverse ray tracing to simulate the modulation process of structured light field. Li et al [12] improved the calculation efficiency and accuracy of the above system. Haskamp et al [13] developed a virtual measurement system based on ray tracing, but the simulation of lens defocus was not sufficient.…”
Section: Introductionmentioning
confidence: 99%