Our system is currently under heavy load due to increased usage. We're actively working on upgrades to improve performance. Thank you for your patience.
28th Fluid Dynamics Conference 1997
DOI: 10.2514/6.1997-1916
|View full text |Cite
|
Sign up to set email alerts
|

Accuracy study of a 2-component Point Doppler Velocimeter (PDV)

Abstract: A two-component Point Doppler Velocimeter (PDV) which has recently been developed is described, and a series of velocity measurements which have been obtained to quantify the accuracy of the PDV system are summarized. This PDV system uses molecular iodine vapor cells as frequency discriminating filters to determine the Doppler shift of laser light which is scattered off of seed particles in a flow. The majority of results which have been obtained to date are for the mean velocity of a rotating wheel, although … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
15
0

Year Published

1999
1999
2007
2007

Publication Types

Select...
5
1
1

Relationship

1
6

Authors

Journals

citations
Cited by 13 publications
(17 citation statements)
references
References 4 publications
2
15
0
Order By: Relevance
“…An offset on the order of 5 m/s in the DGV measurements has been subtracted from both cuts. The cause of this zero velocity offset is believed to be random, uncorrelated drift in the side arm temperatures of the reference and measurement iodine cells; similar zero offsets were observed in the PDV results of Kuhlman et al 3 The rms deviation of the tangential velocity in Fig. 6 from the known solid body wheel rotation varies from 1.2 to 1.8 m/s for X and Y cuts, with an average rms error of 1.5 m/s, for a series of four runs.…”
Section: Wheel Velocity Resultssupporting
confidence: 69%
See 3 more Smart Citations
“…An offset on the order of 5 m/s in the DGV measurements has been subtracted from both cuts. The cause of this zero velocity offset is believed to be random, uncorrelated drift in the side arm temperatures of the reference and measurement iodine cells; similar zero offsets were observed in the PDV results of Kuhlman et al 3 The rms deviation of the tangential velocity in Fig. 6 from the known solid body wheel rotation varies from 1.2 to 1.8 m/s for X and Y cuts, with an average rms error of 1.5 m/s, for a series of four runs.…”
Section: Wheel Velocity Resultssupporting
confidence: 69%
“…However, large errors in mean and rms velocities were found near the edges of the jet, probably due to uneven seeding and low signal-to-noise ratio. Similar PDV studies have been conducted by Morrison et al, 14 Roehle and Schodl, 15 and Kuhlman et al 3 More recently, McKenzie, 1 , 16 Smith and Northam, 2 Smith, 17 Irani, 18 and Irani and Miller, 19 Elliott et al, 20 , 21 Clancy et al, 22 Mosedale et al, 23 Reinath, 24 Beutner and Baust, 25 Beutner et al, 26 and Ainsworth and Thorpe 27 have also developed DGV systems. Meyers 28 describes recent improvements to his DGV systems.…”
Section: Literature Summarysupporting
confidence: 55%
See 2 more Smart Citations
“…The point technique relies on photo-diodes to measure light intensity through the same type of molecular iodine cells used by Meyers at NASA Langley. Later work added a second photo-diode to measure two velocity component data on a rotating wheel and achieved uncertainties less than 1 ™ [25]. Expanding on the work for the point system, Naylor developed a two component camera based DGV [20,27].…”
Section: University Dgv Researchmentioning
confidence: 99%