2023
DOI: 10.3390/dj11050123
|View full text |Cite
|
Sign up to set email alerts
|

Accuracy of Zygomatic Implant Placement Using a Full Digital Planning and Custom-Made Bone-Supported Guide: A Retrospective Observational Cohort Study

Abstract: The aim of the study was to evaluate the accuracy of zygomatic implant placement using customized bone-supported laser-sintered titanium templates. Pre-surgical computed tomography (CT) scans allowed to develop the ideal virtual planning for each patient. Direct metal laser-sintering was used to create the surgical guides for the implant placement. Post-operative CT scans were taken 6 months after surgery to assess any differences between the planned and placed zygomatic implants. Qualitative and quantitative … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
9
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(10 citation statements)
references
References 29 publications
0
9
0
Order By: Relevance
“…After removing duplicates ( n = 56), 51 articles were screened using title-abstract-keyword reading, leaving 35 reports eligible (substantial agreement, κ = 0.95). After full-text reading and a subsequent search for relevant citations, 14 studies were included in this systematic review [ 8 , 10 , 11 , 12 , 13 , 14 , 15 , 19 , 32 , 33 , 34 , 35 , 36 , 37 ] (100% of agreement among the reviewers) ( Figure 1 ). One current retrospective study from Wu included [ 19 ], and other fives studies from the same team (Shanghai Jiaotong University) were excluded due to the same population were collected in Wu’s publication [ 19 ].…”
Section: Resultsmentioning
confidence: 99%
See 4 more Smart Citations
“…After removing duplicates ( n = 56), 51 articles were screened using title-abstract-keyword reading, leaving 35 reports eligible (substantial agreement, κ = 0.95). After full-text reading and a subsequent search for relevant citations, 14 studies were included in this systematic review [ 8 , 10 , 11 , 12 , 13 , 14 , 15 , 19 , 32 , 33 , 34 , 35 , 36 , 37 ] (100% of agreement among the reviewers) ( Figure 1 ). One current retrospective study from Wu included [ 19 ], and other fives studies from the same team (Shanghai Jiaotong University) were excluded due to the same population were collected in Wu’s publication [ 19 ].…”
Section: Resultsmentioning
confidence: 99%
“…The main characteristics of the included studies are described in Table 1 according to guidance approach, system, number of examinations, ZI characteristics, and conclusions. A total of 14 studies [ 8 , 10 , 11 , 12 , 13 , 14 , 15 , 19 , 32 , 33 , 34 , 35 , 36 , 37 ], including one RCT [ 32 ], two retrospective studies [ 15 , 19 ], five prospective studies [ 12 , 13 , 33 , 34 , 37 ], six cadaver studies with one comparative analysis [ 8 , 10 , 11 , 14 , 35 , 36 ], were retrieved from the search. Those reported ZI planned/placed accuracy in 144 patients (77 male and 67 female) and 35 cadavers with total of 511 ZIs (Nobel Biocare: 274, Southern Implant: 42, SIN Implant: 16, non-mentioned: 179); six studies used 35 cadavers with 118 ZIs.…”
Section: Resultsmentioning
confidence: 99%
See 3 more Smart Citations