Accuracy of ultrasonography in assessing spleen and liver size in patients with Gaucher disease: comparison to computed tomographic measurements

Abstract: A comparison was made between volume measurements of spleen and liver by ultrasonography and by computed tomography, the two most common modes of assessment of organ size in patients with Gaucher disease, who require frequent follow‐up measurements. The two measurements showed a high degree of correlation within a broad range for both spleen and liver volumes. An algorithm for conversion of one measurement to the other was derived for both spleen and liver.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
60
0

Year Published

1998
1998
2015
2015

Publication Types

Select...
9

Relationship

0
9

Authors

Journals

citations
Cited by 68 publications
(60 citation statements)
references
References 3 publications
0
60
0
Order By: Relevance
“…Ultrasound measurements are converted to volumetric equivalents using the formula of Elstein et al [34]. Registry procedures recommend technological consistency for serial volumetric measurements, but compliance was not verified for each patient.…”
Section: Therapeutic Goalsmentioning
confidence: 99%
“…Ultrasound measurements are converted to volumetric equivalents using the formula of Elstein et al [34]. Registry procedures recommend technological consistency for serial volumetric measurements, but compliance was not verified for each patient.…”
Section: Therapeutic Goalsmentioning
confidence: 99%
“…My experience with ultrasound scanning for routine follow-up of organ volumes has been rewarding despite reliance on a single radiologist 31 ; for specific indications and for clinical trial assessments, magnetic resonance imaging is preferable.…”
Section: Imaging Modalitiesmentioning
confidence: 99%
“…[1][2][3][4][5][6][7] In addition to diagnosis, organ volume/height measurements have also been found to be important in making surgical decisions involving organ transplantation. [8][9][10] In traditional clinical practice, 3D organ analysis is performed via time-consuming manual measurements; alternatively, the evaluation is based on 2D projection images, which introduces bias.…”
Section: Introductionmentioning
confidence: 99%