Our system is currently under heavy load due to increased usage. We're actively working on upgrades to improve performance. Thank you for your patience.
2021
DOI: 10.1016/j.wneu.2020.10.063
|View full text |Cite
|
Sign up to set email alerts
|

Accuracy of S2 Alar-Iliac Screw Placement Under the Guidance of a 3D-Printed Surgical Guide Template

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
9
0
4

Year Published

2022
2022
2024
2024

Publication Types

Select...
6

Relationship

1
5

Authors

Journals

citations
Cited by 9 publications
(13 citation statements)
references
References 33 publications
0
9
0
4
Order By: Relevance
“… 2021 Zhao Y et al. [ 10 ] World Neurosurg 27 S2AI screw for degenerative scoliosis, revision surgery, spondylolisthesis, and lumbar stenosis S2AI screw placement assisted by a 3D-printed surgical guide is safe and accurate. 2021 Liang W et al.…”
Section: Basic Types and Clinical Applications Of Orthopedic 3d Print...mentioning
confidence: 99%
See 2 more Smart Citations
“… 2021 Zhao Y et al. [ 10 ] World Neurosurg 27 S2AI screw for degenerative scoliosis, revision surgery, spondylolisthesis, and lumbar stenosis S2AI screw placement assisted by a 3D-printed surgical guide is safe and accurate. 2021 Liang W et al.…”
Section: Basic Types and Clinical Applications Of Orthopedic 3d Print...mentioning
confidence: 99%
“…Sacral fractures are a common clinical disease. In the placement of S2 Alar-Iliac (S2AI) screws, many surgeons used a 3D printing surgical guide [ 10 , 104 ]. Compared to the freehand screw placement group, it showed a higher accuracy rate with the use of a guide template.…”
Section: Basic Types and Clinical Applications Of Orthopedic 3d Print...mentioning
confidence: 99%
See 1 more Smart Citation
“…A similar result was found by Zhao et al, who utilized bilateral S2AI placement under guidance of a 3D printed surgical template for 27 patients in a retrospective clinical study in which placement of the screw was postoperatively graded on a scale ranging from grade 0(screw fully surrounded by bone) to grade 3(severe, breakthrough distance >6 mm), with the breakthrough distance defined as the shortest distance from the furthest end of the penetrating screw to the adjacent cortical bone. 18 During the operation, all screws were successfully placed in the ilium, except for 2 screws that slightly invaded the medial cortical bone (grade 1). Therefore, the results from studies regarding screw misplacement yield the conclusion that small variations in angulation can produce potential breaches, and that although such breaches may or may not result in complications, they can occur relatively frequently.…”
Section: Complications In Freehand S2 Alar Iliac Techniquesmentioning
confidence: 99%
“…Высокая точность транспедикулярной имплантации при использовании персонифицированных навигационных шаблонов подтверждается многочисленными современными исследованиями [1][2][3][4][5]. Изготовление таких шаблонов требует определенных финансовых, технических и временных ресурсов [6][7][8][9]. Особое значение они имеют при планировании протяженной фиксации с многочисленными опорными элементами, при этом логично их изготавливать только для тех зон позвоночника, в которых установка транспедикулярных винтов может представлять техническую сложность.…”
unclassified