2020
DOI: 10.1016/j.measurement.2020.107558
|View full text |Cite
|
Sign up to set email alerts
|

Accuracy of roundness assessment using air gauge with the slot-shaped measuring nozzle

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
5
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
8

Relationship

0
8

Authors

Journals

citations
Cited by 8 publications
(5 citation statements)
references
References 19 publications
0
5
0
Order By: Relevance
“…There are some reports, though, demonstrating that in some conditions waviness of the profile Wt can be measured relatively accurately, with relative error of 5% [ 82 ]. Jakubowicz [ 83 ] proposed and investigated a roundness measuring air gauge with slot-shaped measuring nozzle. To assess ability of the as-modified air gauge, the author made a quantitative comparison with a reference method, calculating a relative error δRONt represented by a ratio of the difference between averages of pneumatic and stylus measurement results: where and are roundness deviations calculated according to the standard ISO 12181-2011 for least squares fit of points collected with the tested pneumatic system and reference Hommel-Etamic roundscan 535 system, respectively.…”
Section: Research Directions In Recent Papersmentioning
confidence: 99%
“…There are some reports, though, demonstrating that in some conditions waviness of the profile Wt can be measured relatively accurately, with relative error of 5% [ 82 ]. Jakubowicz [ 83 ] proposed and investigated a roundness measuring air gauge with slot-shaped measuring nozzle. To assess ability of the as-modified air gauge, the author made a quantitative comparison with a reference method, calculating a relative error δRONt represented by a ratio of the difference between averages of pneumatic and stylus measurement results: where and are roundness deviations calculated according to the standard ISO 12181-2011 for least squares fit of points collected with the tested pneumatic system and reference Hommel-Etamic roundscan 535 system, respectively.…”
Section: Research Directions In Recent Papersmentioning
confidence: 99%
“…Various authors have dealt with different ways to improve the performance of pneumatic comparators. The influence of the measuring nozzle tip geometry was the subject of [10][11][12][13][14]. It was shown in these papers that fouling of the measuring nozzle head can be reduced by altering the geometry of the nozzle head.…”
Section: Introductionmentioning
confidence: 99%
“…Huang et al propose an asymptotic search method in the paper [9] to obtain the coordinates of the concentric circles of the minimum zone model and calculate the roundness error. Jakubowicz et al discuss application of the slot-shaped nozzles in the air gauges for the roundness assessment in the paper [10]. Huang et al propose an improved method that integrates a bidirectional search of unequal probability and an offset movement mechanism, and the method can quickly and accurately evaluate the roundness.…”
Section: Introductionmentioning
confidence: 99%