2008
DOI: 10.1016/j.ijcard.2007.05.010
|View full text |Cite
|
Sign up to set email alerts
|

Accuracy of real-time 3D echocardiography in the evaluation of functional anatomy of mitral regurgitation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
27
0
3

Year Published

2008
2008
2017
2017

Publication Types

Select...
7
2
1

Relationship

0
10

Authors

Journals

citations
Cited by 50 publications
(31 citation statements)
references
References 20 publications
1
27
0
3
Order By: Relevance
“…Ahmed and colleagues have shown that there might be a difference between the surgical inspection and the echocardiographic finding, especially in nonpronounced prolapses. [12] Grewal et al [13] had 2 different echocardiographers performing the 2D and 3D views, and the results were analyzed at a later time. Because it was an offline analyses, the echocardiographers had assessed the stored loops and had not performed the TEE examination themselves, at that point of time.…”
Section: Discussionmentioning
confidence: 99%
“…Ahmed and colleagues have shown that there might be a difference between the surgical inspection and the echocardiographic finding, especially in nonpronounced prolapses. [12] Grewal et al [13] had 2 different echocardiographers performing the 2D and 3D views, and the results were analyzed at a later time. Because it was an offline analyses, the echocardiographers had assessed the stored loops and had not performed the TEE examination themselves, at that point of time.…”
Section: Discussionmentioning
confidence: 99%
“…The diagnostic accuracy of RT3DE evaluation of functional anatomy of mitral regurgitation also was demonstrated recently against surgical findings. 73 The more complex the mitral lesion is, the more valuable 3D echocardiography is compared with 2D TEE. 74 An important technological advancement in the last 3 years was the development of dedicated software to allow advanced 3D rendering of the valves and quantitative analysis of mitral apparatus geometry (Figure 12).…”
Section: Mor-avi Et Almentioning
confidence: 99%
“…12 Recent reports indicate that TEE accurately and consistently demonstrates mitral leaflet dysfunction. [13][14][15][16][17] However, the efficacy of echo-guided mitral repair has not been established. 18,19 We developed a succinct set of precisely defined images observed to be highly concordant with intraoperative findings.…”
Section: Clinical Perspective On P 141mentioning
confidence: 99%