2007
DOI: 10.1016/j.arth.2006.10.001
|View full text |Cite
|
Sign up to set email alerts
|

Accuracy of Navigation-Assisted Acetabular Component Positioning Studied by Computed Tomography Measurements

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

3
84
1

Year Published

2007
2007
2020
2020

Publication Types

Select...
10

Relationship

1
9

Authors

Journals

citations
Cited by 81 publications
(88 citation statements)
references
References 15 publications
3
84
1
Order By: Relevance
“…In this context, combined femoral and acetabular component navigation represents an appealing concept to further optimise implant orientation potentially improving the clinical outcome in HR. However, there is a need to overcome limitations associated with acetabular component navigation with regard to accuracy and practicability of landmark registration [45].…”
Section: Systematic Review Resultsmentioning
confidence: 99%
“…In this context, combined femoral and acetabular component navigation represents an appealing concept to further optimise implant orientation potentially improving the clinical outcome in HR. However, there is a need to overcome limitations associated with acetabular component navigation with regard to accuracy and practicability of landmark registration [45].…”
Section: Systematic Review Resultsmentioning
confidence: 99%
“…The authors have recently provided data from a prospective study of 37 patients (20 females, 17 males, mean age 65 years, and 18 right and 19 left hip joints) undergoing THAs with the PiGalileo THR system at four contributing centers [16]. All patients received a cementless threaded biconical cup of pure titanium with a polyethylene inlay and a cementless tapered straight titanium alloy stem with a ceramic ball head (Plus Orthopedics, Rotkreuz, Switzerland).…”
Section: Ct-free Navigationmentioning
confidence: 99%
“…Superior femoral neck notching may be caused by inferior or valgus malpositioning of the femoral component and has been implicated in mechanical weakening [18,20] of the femoral neck and impairment of vascularity of the femoral head [3]. Studies on the use of computer navigation in THA have shown an improvement in acetabular component alignment in patients when compared with a conventional jig-based technique [10,11,13,14,26,27]. These studies all examined placement of the acetabular cup using navigation and concluded navigation in THA improves accuracy of cup placement by decreasing the number of outliers from the desired alignment.…”
Section: Introductionmentioning
confidence: 99%