Accuracy of Measurements of Thermophysical Parameters by Dual-Beam Thermal-Lens Spectrometry

Abstract: Thermal-lens spectrometry is a sensitive technique for determination of physicochemical properties and thermophysical parameters of various materials including heterogeneous systems and nanoparticles. In this paper, we consider the issues of the correctness (trueness) of measurements of the characteristic time of the thermal-lens effect and, thus, of the thermal diffusivity determined by dual-beam mode-mismatching thermal lensing. As sources of systematic errors, major factors—radiation sources, sample-cell an… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
15
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
4
1

Relationship

1
4

Authors

Journals

citations
Cited by 8 publications
(15 citation statements)
references
References 99 publications
0
15
0
Order By: Relevance
“…For thermal lens experiments, a coaxial two-laser spectrometer was used [ 33 , 64 ]. The thermal lens is induced in the cell by the radiation from an Innova 90-6 argon ion laser (Coherent, Palo Alto, CA, USA) with generation wavelength of 514.5 nm (TEM 00 mode; maximum output radiation power, 1.5 W).…”
Section: Methodsmentioning
confidence: 99%
“…For thermal lens experiments, a coaxial two-laser spectrometer was used [ 33 , 64 ]. The thermal lens is induced in the cell by the radiation from an Innova 90-6 argon ion laser (Coherent, Palo Alto, CA, USA) with generation wavelength of 514.5 nm (TEM 00 mode; maximum output radiation power, 1.5 W).…”
Section: Methodsmentioning
confidence: 99%
“…Ferroin was added to each sample. To reduce the systematic error caused by high absorbance, as described [23], the concentration of ferroin in the dispersions did not exceed 1 µmol/L. After that, the dispersions were mixed for 2 h on a laboratory shaker and used in the analysis.…”
Section: Reagents and Chemicalsmentioning
confidence: 99%
“…The shutter frequency corresponds to the time of full development of the thermal lens and the transient curve reach the steady state. The selection of the number of transient curves for averaging is based on the recommendations made in [23]. The mode-mismatch factor was selected based on the condition of the minimum systematic error identified in [23] and corresponding to the conditions of the model [22].…”
Section: Thermal-lens Spectrometermentioning
confidence: 99%