Accuracy of GafChromic EBT Film as Dose Meter in Radiotherapy QA

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
4
0

Year Published

2011
2011
2020
2020

Publication Types

Select...
3

Relationship

0
3

Authors

Journals

citations
Cited by 3 publications
(4 citation statements)
references
References 7 publications
0
4
0
Order By: Relevance
“…Because EBT2 film partially polarizes transmitted light, 22 the doses calculated using images from a CCD scanner may show substantial lateral distortions. 16,20,21,23 The multichannel technique is able to mitigate this lateral dependence. To demonstrate this, one of the EBT2 films exposed to a 10 m  10 cm field and used to generate the calibration curve shown in Table I was scanned in the center of an Epson 10000XL scanner and then moved to a new position displaced "4" laterally from the center of the scanner and rescanned a position close to the left edge of the scan window.…”
Section: Iiid Mitigation Of Lateral Displacement Effectmentioning
confidence: 99%
See 1 more Smart Citation
“…Because EBT2 film partially polarizes transmitted light, 22 the doses calculated using images from a CCD scanner may show substantial lateral distortions. 16,20,21,23 The multichannel technique is able to mitigate this lateral dependence. To demonstrate this, one of the EBT2 films exposed to a 10 m  10 cm field and used to generate the calibration curve shown in Table I was scanned in the center of an Epson 10000XL scanner and then moved to a new position displaced "4" laterally from the center of the scanner and rescanned a position close to the left edge of the scan window.…”
Section: Iiid Mitigation Of Lateral Displacement Effectmentioning
confidence: 99%
“…A multichannel scanner provides a choice of colors for scanning and this has been useful in offering the selection of the red color channel for greater sensitivity at lower doses, yet being able to extend the dynamic range of the film to much higher doses using the green of blue channels. [6][7][8][9]13 However, a number of investigators 11,12,14,15,21 have pointed to challenges in radiochromic film dosimetry, particularly those related to the scanning of the radiochromic film. To date, radiochromic film dosimetry has relied on the use of information from a single color channel of an red-bluegreen (RGB) scanner.…”
Section: Introductionmentioning
confidence: 99%
“…Our institution has vast experience in film dosimetry for dosimetric plan QA and end-to-end testing (van Battum et al 2008(van Battum et al , 2009(van Battum et al , 2016. EBT3 GafChromic film (Ashland Inc.) is a suitable tool for absolute 2D measurement of photon beams.…”
mentioning
confidence: 99%
“…Films were digitized using a transmission flatbed scanner (Epson Expression 1680 Pro). All films were scanned in portrait mode along the central axis of the scanner in order to avoid lateral scanner artifacts (Battum and Hoffmans 2009). Film transmission values were translated to absolute dose (DOSE FILM ) by means of a triple-color calibration method and generating a calibration curve with Matlab (R2015b, Mathworks) (Mayer et al 2012).…”
Section: Film Dosimetrymentioning
confidence: 99%