2014
DOI: 10.1016/j.gaitpost.2013.07.010
|View full text |Cite
|
Sign up to set email alerts
|

Accuracy of force and center of pressure measures of the Wii Balance Board

Abstract: The Nintendo Wii Balance Board (WBB) is increasingly used as an inexpensive force plate for assessment of postural control; however, no documentation of force and COP accuracy and reliability is publicly available. Therefore, we performed a standard measurement uncertainty analysis on 3 lightly and 6 heavily used WBBs to provide future users with information about the repeatability and accuracy of the WBB force and COP measurements. Across WBBs, we found the total uncertainty of force measurements to be within… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

8
115
2
4

Year Published

2016
2016
2020
2020

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 165 publications
(135 citation statements)
references
References 14 publications
(18 reference statements)
8
115
2
4
Order By: Relevance
“…For example, WBB measurements may be associated with greater uncertainty than laboratorygrade equipment. 6 However, the greatest variability has been observed across different WBBs, and the use of a single WBB, as was the case in the current study, optimized repeatability. 6 Importantly, the accuracy of CoP measurements does not appear to diminish with repeated use of a single WBB over time.…”
mentioning
confidence: 60%
See 2 more Smart Citations
“…For example, WBB measurements may be associated with greater uncertainty than laboratorygrade equipment. 6 However, the greatest variability has been observed across different WBBs, and the use of a single WBB, as was the case in the current study, optimized repeatability. 6 Importantly, the accuracy of CoP measurements does not appear to diminish with repeated use of a single WBB over time.…”
mentioning
confidence: 60%
“…6 However, the greatest variability has been observed across different WBBs, and the use of a single WBB, as was the case in the current study, optimized repeatability. 6 Importantly, the accuracy of CoP measurements does not appear to diminish with repeated use of a single WBB over time. 6 While other issues such as sampling-rate irregularity via the Bluetooth protocol are inherent in the system, excellent validity and reliability results using an identical protocol support its use.…”
mentioning
confidence: 60%
See 1 more Smart Citation
“…A sample of healthy subjects and individuals with stroke were assessed with the system and compared, as a proof of the clinical utility of the assessment tool. In spite of the fact that the WBB seems to not be as accurate as laboratory grade force platforms [30], it appears sufficient for detecting postural reactions during posturography tests. However, the particular hardware architecture of each posturography system can lead to different measurements [30], therefore the WBB-based posturography system should be used for relative rather than for absolute measurements.…”
Section: Discussionmentioning
confidence: 94%
“…Such devices are used in the measurements of ground reaction forces [11,12]. The system will be integrated with a PC with the use of the LabVIEW software.…”
Section: Discussionmentioning
confidence: 99%