2019
DOI: 10.1016/j.prosdent.2018.10.017
|View full text |Cite
|
Sign up to set email alerts
|

Accuracy of capturing oncology facial defects with multimodal image fusion versus laser scanning

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

0
4
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
7

Relationship

0
7

Authors

Journals

citations
Cited by 9 publications
(4 citation statements)
references
References 16 publications
(29 reference statements)
0
4
0
Order By: Relevance
“…The capture time of 3D facial imaging system is 50 ms and its accuracy is within 500 μm [ 31 ]. Although the mean global deviation between the multimodal image fusion model (220 ± 50 μm) and the laser-scanned model (170 ± 70 μm) showed the statistically significant difference, the mean difference of 500 μm is unlikely to have a clinical impact [ 32 ].…”
Section: Discussionmentioning
confidence: 99%
“…The capture time of 3D facial imaging system is 50 ms and its accuracy is within 500 μm [ 31 ]. Although the mean global deviation between the multimodal image fusion model (220 ± 50 μm) and the laser-scanned model (170 ± 70 μm) showed the statistically significant difference, the mean difference of 500 μm is unlikely to have a clinical impact [ 32 ].…”
Section: Discussionmentioning
confidence: 99%
“…A preliminary extraoral irreversible hydrocolloid impression was made from the patient's face. A custom impression tray was fabricated to get a detailed impression of the intaglio surface with a low‐viscosity light‐body polyvinyl siloxane silicone impression material (Elite HD Plus, Zhermack, Italy) applying minimal pressure to overcome the inaccuracies 1,10 …”
Section: Clinical Reportmentioning
confidence: 99%
“…A custom impression tray was fabricated to get a detailed impression of the intaglio surface with a lowviscosity light-body polyvinyl siloxane silicone impression material (Elite HD Plus, Zhermack, Italy) applying minimal pressure to overcome the inaccuracies. 1,10 A wax moulage replacing the missing outer facial contours was made and tried on the patient's face. A substructure was designed considering wax moulage as a reference so that it would support the silicone MFP and provide the nasal airway (Figure 4a,b).…”
Section: Prosthetic Proceduresmentioning
confidence: 99%
“…CT scans have a unique use for extraoral surface data acquisition only when osseointegrated implants are being planned. It can help transport the head's position and allow the designer to mirror the healthy anatomy with just one scan (23,26,27,(36)(37)(38)(39)(40)(41).…”
Section: Molding Processes Have Been Utilizing Different 3d Image Acq...mentioning
confidence: 99%