2014
DOI: 10.1007/s00264-014-2292-3
|View full text |Cite
|
Sign up to set email alerts
|

Accuracy of bony landmarks for restoring the natural joint line in revision knee surgery: an MRI study

Abstract: Purpose Restoring the joint line (JL) improves clinical and functional outcome in total knee arthroplasty (TKA). Therefore, anatomical landmarks to approximate the JL have been published. So far, the natural deviation of the JL 90°to the mechanical tibial axis has not been considered. Thus, we designed this study to: (1) determine the natural JL of knees in healthy persons in respect to the mechanical tibial axis, (2) validate and double-check intra-operative bony landmarks already been published in respect to… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
21
1
1

Year Published

2014
2014
2023
2023

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 26 publications
(25 citation statements)
references
References 19 publications
2
21
1
1
Order By: Relevance
“…The one-way ANOVA test did not reveal a significant difference (F test not significant) in the intra and inter-observer reliability of the ATJL and FD measurements (Table 1 ). These findings are identical to Clement et al ( 2014 ) who also proved the reliability of the FD measurement, as well as Iacono et al ( 2013 ) and Maderbacher et al Maderbacher et al 2014 ) who confirmed likewise the reliability of the ATJL measurement. In addition, Romero et al ( 2010 ) had similar findings concerning distal femoral measurements.…”
Section: Resultssupporting
confidence: 89%
“…The one-way ANOVA test did not reveal a significant difference (F test not significant) in the intra and inter-observer reliability of the ATJL and FD measurements (Table 1 ). These findings are identical to Clement et al ( 2014 ) who also proved the reliability of the FD measurement, as well as Iacono et al ( 2013 ) and Maderbacher et al Maderbacher et al 2014 ) who confirmed likewise the reliability of the ATJL measurement. In addition, Romero et al ( 2010 ) had similar findings concerning distal femoral measurements.…”
Section: Resultssupporting
confidence: 89%
“…[ 5 ] Maderbacher et al . [ 14 ] and Iacono et al . [ 15 16 ] concluded that the femoral adductor tubercle was an accurate and stable anatomical landmark for measurement of knee JL position, and that its position was not affected by knee flexion or extension.…”
Section: Discussionmentioning
confidence: 99%
“…The posterior medial articular distance (PMAD) and posterior lateral articular distance (PLAD) were defined as the distance between the most prominent points of the medial and lateral epicondyles and the posterior joint lines/posterior articular surfaces of the medial and lateral condyles perpendicular to the anatomical axis of the femur in the sagittal plane. The anatomical axis of the femur and the joint line were determined as previously described by Maderbacher et al 9 , 12 In brief, the femoral mechanical axis is defined as the line from the midpoint of the centre of the shaft to the midpoint of the distal femur, and the joint line defined as the line tangent to the most distal points of both the medial and the lateral femoral condylar articular surfaces. The most prominent points of the medial and lateral epicondyles and the joint lines were re-identified for each measurement ( Fig.…”
Section: Methodsmentioning
confidence: 99%
“…This issue still remains an object of interest. 9 - 11 The present study aimed to identify an accurate, reliable and easily performed standardised method for determining the correct anatomical position of the joint line intra-operatively during revision TKA. The hypothesis was that a ratio could be determined based on the distal and posterior articular distances from the epicondyles to indicate the imaginary borders of the distal femur and the level of the joint line in revision TKA, and therefore enable an accurate decision regarding the size and location of the femoral component.…”
Section: Introductionmentioning