2020
DOI: 10.1136/heartjnl-2019-316004
|View full text |Cite
|
Sign up to set email alerts
|

Accuracy of a smartwatch based single-lead electrocardiogram device in detection of atrial fibrillation

Abstract: ObjectiveThe AliveCor KardiaBand (KB) is an Food and Drug Administration-approved smartwatch-based cardiac rhythm monitor that records a lead-Intelligent ECG (iECG). Despite the appeal of wearable integrated ECG devices, there is a paucity of data evaluating their accuracy in diagnosing atrial fibrillation (AF). We evaluated whether a smartwatch-based device for AF detection is an accurate tool for diagnosing AF when compared with 12-lead ECG.MethodsA prospective, multi-centre, validation study was conducted i… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1

Citation Types

5
43
0
3

Year Published

2020
2020
2024
2024

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 79 publications
(51 citation statements)
references
References 23 publications
5
43
0
3
Order By: Relevance
“…In einer prospektiven multizentrischen Studie an 200 Patienten (38 mit Vorhofflimmern,162 mit Sinusrhythmus) konnte mit dem KB im Vergleich zu einem 12-Kanal-EKG eine Sensitivität von 94,4 % und eine Spezifität von 81,9 % erreicht werden [35]. Allerdings waren 19,5 % der Aufzeichnungen entweder nicht als Sinusrhythmus oder Vorhofflimmern interpretiert worden (12,5 %) bzw.…”
Section: Wearables Zur Detektion Von Vorhofflimmern -Studien An Patieunclassified
See 2 more Smart Citations
“…In einer prospektiven multizentrischen Studie an 200 Patienten (38 mit Vorhofflimmern,162 mit Sinusrhythmus) konnte mit dem KB im Vergleich zu einem 12-Kanal-EKG eine Sensitivität von 94,4 % und eine Spezifität von 81,9 % erreicht werden [35]. Allerdings waren 19,5 % der Aufzeichnungen entweder nicht als Sinusrhythmus oder Vorhofflimmern interpretiert worden (12,5 %) bzw.…”
Section: Wearables Zur Detektion Von Vorhofflimmern -Studien An Patieunclassified
“…Allerdings waren 19,5 % der Aufzeichnungen entweder nicht als Sinusrhythmus oder Vorhofflimmern interpretiert worden (12,5 %) bzw. waren durch Artefakte nicht analysierbar [35].…”
Section: Wearables Zur Detektion Von Vorhofflimmern -Studien An Patieunclassified
See 1 more Smart Citation
“…A relevant question is whether or not automated diagnoses provided by a mobile device are an adequate substitution for healthcare provider interpretation. The investigators of this study evaluated whether a smartwatch-based device for AF detection with an automatic interpretation is an accurate tool for diagnosing AF when compared with a physician-interpreted, standard 12-lead ECG 5. The authors studied hospital inpatients using AliveCor’s KardiaBand.…”
mentioning
confidence: 99%
“…Smartwatch-based devices for monitoring heart rate and rhythm are increasingly popular with patients but many physicians are concerned about accuracy for detection of atrial fibrillation (AF). In a prospective multi-centre study, Rajakariar and colleagues1 compared automated smartwatch diagnosis of AF plus recording of a lead-intelligent ECG (iECG) with a conventional 12-lead ECG recorded immediately after the iECG in 200 hospitalised patients. Overall, accuracy of the smartwatch-based iECG was high at 84% with a negative predictive value 98% but positive predictive value was only 55%, indicating that physician involvement is essential when the smartwatch-based device suggests AF might be present (table 1).…”
mentioning
confidence: 99%