2019
DOI: 10.1111/jopr.13107
|View full text |Cite
|
Sign up to set email alerts
|

Accuracy of 3D Printed Models Created by Two Technologies of Printers with Different Designs of Model Base

Abstract: Purpose To evaluate the accuracy of three‐dimensional (3D) printed models manufactured using two different printer technologies with different model base designs. Materials and Methods A maxillary typodont was scanned using a desktop scanner to generate the Standard Tessellation Language (STL) file as a reference scan. After the scanning procedure, the STL file was exported to Model Builder™ for designing the following two types of the model bases: a solid base design and a hollow base design with a 2.0 mm thi… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
5

Citation Types

4
125
0
1

Year Published

2020
2020
2024
2024

Publication Types

Select...
2
2
2

Relationship

0
6

Authors

Journals

citations
Cited by 129 publications
(145 citation statements)
references
References 15 publications
4
125
0
1
Order By: Relevance
“…Twenty-four studies included reference models as controls in their methodology design [ 6 , 7 , 34 , 36 , 37 , 38 , 39 , 40 , 41 , 42 , 43 , 44 , 45 , 46 , 47 , 48 , 49 , 50 , 51 , 52 , 53 , 55 , 56 , 57 ]. The controls included were a dental stone cast ( n = 8), a digital STL image of a dental stone cast ( n = 3), typodont digital STL image ( n = 7), typodont ( n = 1), prefabricated resin model digital STL image ( n = 2), patient intraoral scan image (2) or a dry human skull ( n = 1).…”
Section: Resultsmentioning
confidence: 99%
See 4 more Smart Citations
“…Twenty-four studies included reference models as controls in their methodology design [ 6 , 7 , 34 , 36 , 37 , 38 , 39 , 40 , 41 , 42 , 43 , 44 , 45 , 46 , 47 , 48 , 49 , 50 , 51 , 52 , 53 , 55 , 56 , 57 ]. The controls included were a dental stone cast ( n = 8), a digital STL image of a dental stone cast ( n = 3), typodont digital STL image ( n = 7), typodont ( n = 1), prefabricated resin model digital STL image ( n = 2), patient intraoral scan image (2) or a dry human skull ( n = 1).…”
Section: Resultsmentioning
confidence: 99%
“…The specified printing layer thickness (z-axis resolution) substantially varied amongst studies and ranged from 25–150 μm for SLA, 20–100 μm for DLP, 16–32 μm for MJ, 100–150 μm for FFF and 89–102 μm for BJ. The study using CLIP technology did not specify the layer thickness used [ 53 ]. Most studies did not specify the printing resolution in the x- and y-axes.…”
Section: Resultsmentioning
confidence: 99%
See 3 more Smart Citations