2018
DOI: 10.1109/tim.2017.2761237
|View full text |Cite
|
Sign up to set email alerts
|

Accuracy Enhancement for Noninvasive Glucose Estimation Using Dual-Wavelength Photoacoustic Measurements and Kernel-Based Calibration

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
24
0

Year Published

2018
2018
2023
2023

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 45 publications
(25 citation statements)
references
References 49 publications
0
24
0
Order By: Relevance
“…The figures of merit, such as RMSE and CNR, were utilized extensively in the literature to assess the performance of the reconstructed image quality in PA imaging. 36,77,78,81 The task-based image quality metrics can better assess the reconstructed image quality, 91,92 but use of RMSE and CNR as metrics has been a common practice across tomographic problems. 36,77,78,81 As the main aim of this work has been to introduce a image-guided filter as a fast postprocessing step to improve the image characteristics of the reconstructed image, which was clearly demonstrated through numerical and experimental phantom as well as in-vivo cases, the other metrics were not considered.…”
Section: Resultsmentioning
confidence: 99%
See 1 more Smart Citation
“…The figures of merit, such as RMSE and CNR, were utilized extensively in the literature to assess the performance of the reconstructed image quality in PA imaging. 36,77,78,81 The task-based image quality metrics can better assess the reconstructed image quality, 91,92 but use of RMSE and CNR as metrics has been a common practice across tomographic problems. 36,77,78,81 As the main aim of this work has been to introduce a image-guided filter as a fast postprocessing step to improve the image characteristics of the reconstructed image, which was clearly demonstrated through numerical and experimental phantom as well as in-vivo cases, the other metrics were not considered.…”
Section: Resultsmentioning
confidence: 99%
“…The RMSE is a common metric for assessing the performance of reconstructed images in PAT 23,[77][78][79] and it is defined as follows:…”
Section: Root Mean Square Errormentioning
confidence: 99%
“…RMSE is generally used to compare the reconstruction quality as an absolute metric and is defined as [47,48]:…”
Section: Root Mean Square Error (Rmse)mentioning
confidence: 99%
“…People adhering to noninvasive will take blood glucose values directly by without pulling out the blood, this type of procedure makes the patient relaxed and encouraged to monitor the blood glucose at regular intervals, and even many times a day. According to the latest developments, an inter digital sensor has been used in applications using noninvasive procedures for characterization of liquids in terms examining conductivity and blood permittivity variations as a function of glucose concentration [20]. Such sensors have recently received an intensive attention in healthcare applications for continuous and real-time monitoring of physiological parameters and personal health of patients and non-patients.…”
Section: Design and Dimensional Measurement Ofmentioning
confidence: 99%