2020
DOI: 10.3389/fneur.2020.590825
|View full text |Cite
|
Sign up to set email alerts
|

Accuracy and Workflow Improvements for Responsive Neurostimulation Hippocampal Depth Electrode Placement Using Robotic Stereotaxy

Abstract: Background: Robotic stereotaxy is increasingly common in epilepsy surgery for the implantation of stereo-electroencephalography (sEEG) electrodes for intracranial seizure monitoring. The use of robots is also gaining popularity for permanent stereotactic lead implantation applications such as in deep brain stimulation and responsive neurostimulation (RNS) procedures.Objective: We describe the evolution of our robotic stereotactic implantation technique for placement of occipital-approach hippocampal RNS depth … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1

Citation Types

0
2
0

Year Published

2021
2021
2024
2024

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 8 publications
(2 citation statements)
references
References 14 publications
0
2
0
Order By: Relevance
“…Our full stereotactic workflow has been described in detail. [18] Two trajectories were planned for ablation: left ACC and left MCC. A parasagittal posterior approach was used to insert both optical fibers and cooling cannulas with robotic guidance.…”
Section: Littmentioning
confidence: 99%
“…Our full stereotactic workflow has been described in detail. [18] Two trajectories were planned for ablation: left ACC and left MCC. A parasagittal posterior approach was used to insert both optical fibers and cooling cannulas with robotic guidance.…”
Section: Littmentioning
confidence: 99%
“…The images were volumetrically fused with preoperative planning CT and MRI using ROSA (Zimmer Biomet) robotic navigation software. For further details regarding our robotic stereotactic workflow, see Karas et al (2020) . Using preoperatively created trajectories targeting the Vim and GPi and tractography, 4 targets were planned.…”
Section: Case Descriptionmentioning