Accuracy and trending capability of haemoglobin measurement by noninvasive pulse co-oximetry in anaesthetized horses

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
5
0

Year Published

2024
2024
2024
2024

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(5 citation statements)
references
References 24 publications
(41 reference statements)
0
5
0
Order By: Relevance
“…These findings are similar to those reported in anaesthetised sheep when a Masimo transmission probe was attached to the tongue (bias − 2%, precision 6%) [ 24 ]. These findings are surprising because the Masimo devices use a signal extraction technology that is not found in traditional Nonin devices [ 18 , 23 ]. The signal extraction technology applies adaptive filters that separate the true arterial signal from signals caused by different physiologic artefacts (e.g.…”
Section: Discussionmentioning
confidence: 99%
See 3 more Smart Citations
“…These findings are similar to those reported in anaesthetised sheep when a Masimo transmission probe was attached to the tongue (bias − 2%, precision 6%) [ 24 ]. These findings are surprising because the Masimo devices use a signal extraction technology that is not found in traditional Nonin devices [ 18 , 23 ]. The signal extraction technology applies adaptive filters that separate the true arterial signal from signals caused by different physiologic artefacts (e.g.…”
Section: Discussionmentioning
confidence: 99%
“…The SaO 2 values from the co-oximeter were used as reference measurements and compared against the simultaneous SpO 2 values from the Nonin and Masimo devices. Even though human benchtop co-oximeters have not been validated in rhinoceros, they have been used successfully to validate the use of pulse oximetry in anaesthetised impala [ 25 ] and horses [ 23 , 26 ]. Furthermore, the human benchtop co-oximeters’ algorithms are likely suitable for rhinoceros because the spectrophotometric characteristic of haemoglobin (i.e., infrared absorbance of oxyhaemoglobin and deoxyhaemoglobin) are similar among human, horses and white rhinoceros [ 17 ].…”
Section: Methodsmentioning
confidence: 99%
See 2 more Smart Citations
“…Pulse co-oximeters use transcutaneous technology based on multi-wavelength spectrophotometry for a continuous determination of hemoglobin (SpHb) among other parameters such as oxygen saturation derived from pulse co-oximetry (SpO 2 ), arterial oxygen content derived from pulse co-oximetry CaO 2 (SpOC), methemoglobin (SpMet), carboxyhemoglobin (SpCO), perfusion index (PI), and the plethysmography variability index (PVi) [ 13 , 14 , 17 , 18 ].…”
Section: Introductionmentioning
confidence: 99%