2020
DOI: 10.1053/j.jvca.2020.03.045
|View full text |Cite
|
Sign up to set email alerts
|

Accuracy and Trending Ability of Blood Pressure and Cardiac Index Measured by ClearSight System in Patients With Reduced Ejection Fraction

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4
1

Citation Types

0
10
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 9 publications
(10 citation statements)
references
References 22 publications
0
10
0
Order By: Relevance
“…In this study, we did not provide instructions for the administration of vasoactive drugs or inotropic agents but observed the ability of ClearSight to follow trends before and after TAVI. The time points for comparison were every few tens of seconds in previous studies, but every few tens of minutes in this study, which was more gradual than in previous studies [ 13 , 21 , 22 ]. However, in the present study, the rate of agreement after prosthetic valve deployment according to the four-quadrant plot analysis was 60.3%, which was much lower than the cutoff value for acceptable trending ability (92%) [ 17 ].…”
Section: Discussionmentioning
confidence: 67%
See 1 more Smart Citation
“…In this study, we did not provide instructions for the administration of vasoactive drugs or inotropic agents but observed the ability of ClearSight to follow trends before and after TAVI. The time points for comparison were every few tens of seconds in previous studies, but every few tens of minutes in this study, which was more gradual than in previous studies [ 13 , 21 , 22 ]. However, in the present study, the rate of agreement after prosthetic valve deployment according to the four-quadrant plot analysis was 60.3%, which was much lower than the cutoff value for acceptable trending ability (92%) [ 17 ].…”
Section: Discussionmentioning
confidence: 67%
“…The cutoff for inaccurate CO ClearSight measurements has been reported in previous studies to be a cardiac index < 2.5 (L/min/m 2 ). In this study, 60 (53%) datasets had a cardiac index < 2.5, which may have contributed to the discrepancy between the CO measurement methods [ 21 , 22 ]. We predicted that CO would increase after AS was released during TAVI, and the accuracy of the ClearSight would be within acceptable limits at T3 and T4.…”
Section: Discussionmentioning
confidence: 99%
“…However, the potential utility of this device is not confined solely to TAVR patients. Previous research has indicated the potential benefits of this device in other types of cardiovascular surgeries [8,24,25]. Hence, its accuracy and reliability may extend to broader surgical contexts and patient characteristics.…”
Section: Discussionmentioning
confidence: 99%
“…Based on previous studies on the accuracy of ClearSight™-derived CI in other surgeries [ 24 , 25 ], we aimed to recruit a total of 30 patients, assuming a 10% dropout rate.…”
Section: Discussionmentioning
confidence: 99%