2017
DOI: 10.1016/j.bjps.2017.07.016
|View full text |Cite
|
Sign up to set email alerts
|

Accuracy and reproducibility of a newly developed tool for volume measurements of the arm using 3D stereophotogrammetry

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
12
0

Year Published

2019
2019
2023
2023

Publication Types

Select...
5
1
1

Relationship

0
7

Authors

Journals

citations
Cited by 20 publications
(12 citation statements)
references
References 16 publications
0
12
0
Order By: Relevance
“…Three-dimensional(3D) reconstruction and modeling of hand morphology has been increasingly gaining importance for many purposes, including manufacturing of custom-made glove 1 , analysis of hand surface and volume 2 , 3 , 4 , and designing of hand surgery and humanoid robot hand 5 , 6 , 7 . Various methods of 3D imaging have been extensively applied in oral and maxillofacial surgery as well as plastic surgery 8 11 , because they collect surface data rapidly, non-invasively, accurately, reliably, and cost-effectively.…”
Section: Introductionmentioning
confidence: 99%
“…Three-dimensional(3D) reconstruction and modeling of hand morphology has been increasingly gaining importance for many purposes, including manufacturing of custom-made glove 1 , analysis of hand surface and volume 2 , 3 , 4 , and designing of hand surgery and humanoid robot hand 5 , 6 , 7 . Various methods of 3D imaging have been extensively applied in oral and maxillofacial surgery as well as plastic surgery 8 11 , because they collect surface data rapidly, non-invasively, accurately, reliably, and cost-effectively.…”
Section: Introductionmentioning
confidence: 99%
“…Eight papers reported excellent ICC values for 3DCI. Pooled ICC data showed an ICCintra value of 0.99 (95% CI=0.95, 1.00) (Erends et al, 2014;Öhberg et al, 2014;Buffa et al, 2015;Hameeteman et al, 2016;Verhulst et al, 2017;Karakashian et al, 2018;Preuβ et al, 2018;Binkley et al, 2020) and an ICCinter value of 1.00 (95% CI=0.98, 0.99) (Buffa et al, 2015;Verhulst et al, 2017). The weighted mean SEM was 1.7% (=2.5%) and the weighted mean SDC was 4.7% (=6.9%) (Lu et al, 2013;Buffa et al, 2015;Landau et al, 2018;Preuβ et al, 2018;Lu & Dixon, 2019;Binkley et al, 2020).…”
Section: Reliabilitymentioning
confidence: 98%
“…Advantages of using 3DCI are that it is a simple, fast, accurate, easy to use and safe means of providing limb volumetric measurements (Öhberg et al, 2014;Buffa et al, 2015;Hoevenaren et al, 2015;Cau et al, 2016;Cau et al, 2018;Landau et al, 2018;Binkley et al, 2020). It requires minimal training to operate (Lu et al, 2014;Öhberg et al, 2014;Verhulst et al, 2017), and the single-camera 3DCI devices are portable and relatively inexpensive, especially compared to the perometer (Lu et al, 2014;Buffa et al, 2015;Cau et al, 2016;Verhulst et al, 2017;Cau et al, 2018;Binkley et al, 2020).…”
Section: Benefits and Considerations Of 3dcimentioning
confidence: 99%
See 2 more Smart Citations