2014
DOI: 10.1016/j.joen.2013.09.002
|View full text |Cite
|
Sign up to set email alerts
|

Accuracy and Reliability of Working Length Determination by Gold Reciproc Motor in Reciprocating Movement

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
9
0

Year Published

2016
2016
2022
2022

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 17 publications
(9 citation statements)
references
References 19 publications
0
9
0
Order By: Relevance
“…T he evolution of electronic apex locators (EALs) has reached accuracy levels above 95% depending on the conditions in which they are used (1)(2)(3)(4)(5)(6). These clinical conditions are directly related to the apical fit of the instrument (2, 7, 8), the apical limit of the determination (7,9), the impossibility of foraminal patency (9), the dynamics of the electronic determinations (5,10,11), and so on (12)(13)(14)(15).…”
mentioning
confidence: 99%
“…T he evolution of electronic apex locators (EALs) has reached accuracy levels above 95% depending on the conditions in which they are used (1)(2)(3)(4)(5)(6). These clinical conditions are directly related to the apical fit of the instrument (2, 7, 8), the apical limit of the determination (7,9), the impossibility of foraminal patency (9), the dynamics of the electronic determinations (5,10,11), and so on (12)(13)(14)(15).…”
mentioning
confidence: 99%
“…But the reviewed measurement devices were of older generations. One study compared the accuracy of the integrated apex locator of the RCM in reciprocating mode with two other manual apex locators [ 21 ]. There were no statistical differences between different measurement techniques, which is in concordance with our results.…”
Section: Discussionmentioning
confidence: 99%
“…The TriAuto ZX (J Morita, Tokyo, Japan) endodontic hand piece as well as the Root ZX II (J Morita, Tokyo, Japan) showed acceptable results in determining the WL during rotary root canal preparation [ 17 , 18 ]. Recently, a study evaluated the accuracy of the newer VDW.Gold RECIPROC motor (VDW, Munich, Germany) WL determination during reciprocating motion and found no differences to other apex locators [ 21 ]. The EndoPilot (Schlumbohm, Brokstedt, Germany) is another new generation endodontic motor with continuous WL measuring function.…”
Section: Introductionmentioning
confidence: 99%
“…It has an AAR feature that ceases and reverses the motion when the tip of the instrument hits a slight constriction (1,13,14). Because inaccuracy in WL determination may lead to inadequate debridement of the root canal, this property is of utmost importance, whereas overestimation may result in tissue damage that slows or prevents healing (15). The aim of the current study was to assess the precision of an integrated motor in maintaining the length without violation of the apical-constriction throughout the root canal preparation compared to a standard EAL.…”
Section: Introductionmentioning
confidence: 99%