Accuracy and Reliability of Length Measurements on Three-Dimensional Computed Tomography Using Open-Source OsiriX Software

Abstract: There is a growing interest in three-dimensional computed tomography (3D-CT) as a research tool for the study of bone, joint anatomy, and kinematics. However, when CT data are processed and handled manually using image processing programs to yield 3D image and coordinate value, systematic and random errors should be validated. We evaluated the accuracy and reliability of length measurement on CT with OsiriX software. 3D-CT scans were made of 14 frozen pig knees with five transosseous holes in the metaphyseal p… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1
1

Citation Types

1
65
0
9

Year Published

2012
2012
2021
2021

Publication Types

Select...
6
2
1

Relationship

0
9

Authors

Journals

citations
Cited by 104 publications
(79 citation statements)
references
References 21 publications
(26 reference statements)
1
65
0
9
Order By: Relevance
“…Scans were evaluated using the software program ImageJ (National Institutes of Health, USA, v1.44p) after multiplanar reconstruction using OsiriX (OsiriX, program version 3.7.1, 2011). Linear bony measurements taken from CT scans using OsiriX have been found to be accurate and reliable [15].…”
Section: Methodsmentioning
confidence: 99%
“…Scans were evaluated using the software program ImageJ (National Institutes of Health, USA, v1.44p) after multiplanar reconstruction using OsiriX (OsiriX, program version 3.7.1, 2011). Linear bony measurements taken from CT scans using OsiriX have been found to be accurate and reliable [15].…”
Section: Methodsmentioning
confidence: 99%
“…At our center, the Department of Oral and Maxillofacial Surgery, at Universitas Indonesia, we regularly produce models using a CAD software for DICOM data analysis and an FDM printer, since this method is widely used because of the availability of materials and printers and lower production costs [13,14].…”
Section: Introductionmentioning
confidence: 99%
“…"Osirix MD" é um programa de computador de acesso aberto, regulamentado pelo FDA I como dispositivo para o diagnóstico por imagem em medicina, e que permite reconstruir imagens tridimensionais coordenando dados e diversas mensurações com acurácia elevada, alto índice de correlação intra e interobservador e margem de erro inferior a 0,1 mm (146)(147)(148) .…”
Section: Análise Objetiva De Resultados Por Meio De Ctunclassified