2019
DOI: 10.1111/ner.12934
|View full text |Cite
|
Sign up to set email alerts
|

Accuracy and Precision of the SynchroMed II Pump

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

0
7
0

Year Published

2020
2020
2023
2023

Publication Types

Select...
5
2

Relationship

0
7

Authors

Journals

citations
Cited by 11 publications
(7 citation statements)
references
References 3 publications
0
7
0
Order By: Relevance
“…Two key technical and procedural areas for improvement exist with regards to CNS infusion. First, harnessing technology such as the Synchromed II intrathecal baclofen pump (Medtronic, Minneapolis MN USA) could allow for a slower, more continuous infusion of intrathecal agent without the need of repeated percutaneous access [22] . However, currently there are several barriers including the stability of a stored cellular product within an intrathecal continuous delivery system.…”
Section: Discussionmentioning
confidence: 99%
“…Two key technical and procedural areas for improvement exist with regards to CNS infusion. First, harnessing technology such as the Synchromed II intrathecal baclofen pump (Medtronic, Minneapolis MN USA) could allow for a slower, more continuous infusion of intrathecal agent without the need of repeated percutaneous access [22] . However, currently there are several barriers including the stability of a stored cellular product within an intrathecal continuous delivery system.…”
Section: Discussionmentioning
confidence: 99%
“…The actuation of the IMRD was based solely on magnetic force without any other power sources, thereby eliminating batteries or electronics. This would allow for smaller dimensions and long‐term operation of the device after implantation compared to other implantable devices for on‐demand drug delivery 48,49 . The device size can be further reduced when fabricated in a more sophisticated manufacturing facility 50 .…”
Section: Discussionmentioning
confidence: 99%
“…Considering translational applications, the actuation device housing may need to be made of harder materials, such as metals, to better protect the drug in the device after implantation 48,52 . In our prototype, 12 separate drug reservoirs were used.…”
Section: Discussionmentioning
confidence: 99%
“…Its original iteration, SynchroMed , was approved by FDA in 1991. The list of Synchromed II therapeutic payloads includes baclofen (for the reduction in severe spasticity), morphine, and Ziconotide (for pain management) [ 59 , 60 ].…”
Section: Iddss and Fbr: Current Clinical Landscapementioning
confidence: 99%