2016
DOI: 10.1016/j.ijome.2016.05.006
|View full text |Cite
|
Sign up to set email alerts
|

Accelerated reliability testing of articulated cable bend restrictor for offshore wind applications

Abstract: Power cable failures for offshore marine energy applications are a growing concern since experience from offshore wind has shown repeated failures of interarray and export cables. These failures may be mitigated by dedicated cable protection systems, such as bend restrictors. This paper presents the rationale and the results for accelerated reliability tests of an articulated bend restrictor.The tests are a collaborative effort between the University of Exeter, CPNL Engineering and NSW, supported by the EU MAR… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
7
0

Year Published

2017
2017
2024
2024

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 12 publications
(7 citation statements)
references
References 18 publications
0
7
0
Order By: Relevance
“…In practice, bend stiffeners are used at both ends of the cable to protect it from over-bending and buckling; see [23] for an example. At the time this study was conducted, the design of the bend stiffener for the cable was not available.…”
Section: Stress and Fatigue Damage Evaluationmentioning
confidence: 99%
See 1 more Smart Citation
“…In practice, bend stiffeners are used at both ends of the cable to protect it from over-bending and buckling; see [23] for an example. At the time this study was conducted, the design of the bend stiffener for the cable was not available.…”
Section: Stress and Fatigue Damage Evaluationmentioning
confidence: 99%
“…Their research provided insight into the failure mechanisms of power conductors, and the fatigue properties of the conductors were presented in S-N diagrams. Through accelerated reliability tests, Thies et al [23] investigated the fatigue life of a pipe bend restrictor, which is used to protect static submarine power cables used in offshore wind applications. Hansen-Zahl et al [24] found that the static configuration of umbilicals and risers has a marked impact on their vortex-induced vibrations.…”
Section: Introductionmentioning
confidence: 99%
“…Recertification is also important in creating a level playing field internationally, to avoid dynamics such as those observed in metal recycling with illegal exports and rogue operators that undercut quality undertakings and introduce high price dynamics that constrain investment [232]. Recertification is closely related to reliability testing [27], a concept that finds resonance within the offshore wind literature (e.g., [237,238]).…”
Section: Recertificationmentioning
confidence: 99%
“…The mooring ropes used in the test are of similar material and construction, therefore the test results are deemed to be representative. Similarly, the loading has been carried out using accelerated testing with the assumption that the damage accumulates over the lifetime of the ropes [19]. The correlation between the accelerated rope testing for synthetic ropes under controlled laboratory conditions (DMaC test rig) has been compared with real sea data [20].…”
Section: Limitationsmentioning
confidence: 99%