2011
DOI: 10.1016/j.brachy.2010.06.008
|View full text |Cite
|
Sign up to set email alerts
|

Accelerated partial breast irradiation using the strut-adjusted volume implant single-entry hybrid catheter in brachytherapy for breast cancer in the setting of breast augmentation

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

1
14
0

Year Published

2011
2011
2016
2016

Publication Types

Select...
6
2

Relationship

1
7

Authors

Journals

citations
Cited by 27 publications
(15 citation statements)
references
References 13 publications
1
14
0
Order By: Relevance
“…Combining the data presented in this report with previously reported outcomes from primarily stage 1–2 breast cancer in patients with previous augmentation (210, 12, 14, 15, 17, 18, 20) demonstrate excellent disease control after both whole breast irradiation and APBI. After 0.5 to over 10 years of follow-up, cases treated with adjuvant RT generated a crude local failure rate of 2.3% (5/221) and overall disease free survival rate of 95.5% (211/221).…”
Section: Discussionsupporting
confidence: 70%
See 2 more Smart Citations
“…Combining the data presented in this report with previously reported outcomes from primarily stage 1–2 breast cancer in patients with previous augmentation (210, 12, 14, 15, 17, 18, 20) demonstrate excellent disease control after both whole breast irradiation and APBI. After 0.5 to over 10 years of follow-up, cases treated with adjuvant RT generated a crude local failure rate of 2.3% (5/221) and overall disease free survival rate of 95.5% (211/221).…”
Section: Discussionsupporting
confidence: 70%
“…Our previous publication (19) is the only investigation utilizing external beam rather than brachytherapy, and the only full-length treatment apart from a few case reports (18, 20). Findings from these reports of whole breast or partial breast irradiation are summarized in the Table S1 in Supplementary Material.…”
Section: Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…The CT images were transferred to a Nucletron Oncentra (Elekta Corp., Stockholm, Sweden) planning system. The patient was planned using methodology outlined in the literature 8 , 9 , 10 . The patient was now ready to begin treatment.…”
Section: Methodsmentioning
confidence: 99%
“…SAVI uses 6, 8 or 10 peripheral source channels with one center channel and inserted in collapse form into the tumor cavity through a small incision in the breast. 37,38 The catheters are then expanded to conform to the shape of the cavity and allow for precise delivery of radiation. MammoSite ML consists of a balloon catheter that is inserted into the lumpectomy then expanded, and radiation is delivered through a tiny seed attached to the catheter, irradiating the area surrounding the cavity.…”
Section: Introductionmentioning
confidence: 99%