2017
DOI: 10.1002/mrm.26755
|View full text |Cite
|
Sign up to set email alerts
|

Accelerated MRI of the fetal heart using compressed sensing and metric optimized gating

Abstract: Purpose To develop and validate a method for accelerated time‐resolved imaging of the fetal heart using a combination of compressed sensing (CS) and metric optimized gating (MOG). Theory and Methods Joint optimization of CS and MOG reconstructions was used to suppress competing artifact from random undersampling and ungated cardiac motion. Retrospectively and prospectively undersampled adult and fetal data were used to validate the proposed reconstruction algorithm qualitatively based on visual assessment, and… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

1
26
0

Year Published

2017
2017
2019
2019

Publication Types

Select...
7

Relationship

2
5

Authors

Journals

citations
Cited by 15 publications
(27 citation statements)
references
References 0 publications
1
26
0
Order By: Relevance
“…The entropy metric favors high contrast and has been shown to be sensitive to motion artifacts in MRI (28). The entropy, H, of cine image series HðYÞ ¼ X j2ROI X k jy j;# k j y max ln jy j;# k j y max [13] where signal intensities jy j;# k j were normalized by…”
Section: Discussionmentioning
confidence: 99%
“…The entropy metric favors high contrast and has been shown to be sensitive to motion artifacts in MRI (28). The entropy, H, of cine image series HðYÞ ¼ X j2ROI X k jy j;# k j y max ln jy j;# k j y max [13] where signal intensities jy j;# k j were normalized by…”
Section: Discussionmentioning
confidence: 99%
“…This is an important limitation of this approach, although advances in MR technology such as accelerated imaging acquisitions and higher field strength may overcome these limitations in the future. 59,60 With regard to the implications of these and others' findings regarding the impact of MH on fetal oxygenation, it is although worth noting that the majority of the data refer to acute MH. Additional information regarding the hemodynamic impact of chronic MH would also therefore be helpful to inform the consideration of the utility of long-term transplacental O2 therapy aimed at improving fetal growth.…”
Section: Limitationsmentioning
confidence: 95%
“…Selection is however challenged by limited cardiovascular visualization by ultrasound or in particular diagnoses with a high rate of false positives (Matsui et al, 2008). Self-gated fetal cine cardiovascular magnetic resonance (CMR) imaging has enabled cine CMR for assessing fetal cardiac anatomy and function also in cases where ultrasound is insufficient for diagnosis (Lloyd et al, 2016;Roy et al, 2016;Chaptinel et al, 2017;Haris et al, 2017). One such solution (Haris et al, 2017) based on socalled iterative Golden-angle RAdial Sparse Parallel (iGRASP) MRI (Feng et al, 2014;Wundrak et al, 2016) was applied in the presented case showing how this CMR method can improve diagnostic accuracy and have direct impact on delivery planning.…”
Section: Case Reportmentioning
confidence: 99%