Proceedings of the 7th International Conference on Properties and Applications of Dielectric Materials (Cat. No.03CH37417)
DOI: 10.1109/icpadm.2003.1218566
|View full text |Cite
|
Sign up to set email alerts
|

AC charge injection investigated by means of space charge measurements: threshold and frequency dependence

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

2
12
0

Publication Types

Select...
3
3

Relationship

1
5

Authors

Journals

citations
Cited by 15 publications
(14 citation statements)
references
References 9 publications
2
12
0
Order By: Relevance
“…Dependence of space charge density on supply-voltage frequency. Sinusoidal voltage, poling field 55 kVrms /mm (after [43]). Time dependence of space charge accumulation at 0 and 180° phase angles of the supply voltage, different fields (55 and 20 kVrms/mm, 1 mHz, Figure 4A) and frequencies (1mHz and 0.1Hz, 55 kVrms/mm, Figure 4B).…”
Section: Model Feature Discussionmentioning
confidence: 99%
See 1 more Smart Citation
“…Dependence of space charge density on supply-voltage frequency. Sinusoidal voltage, poling field 55 kVrms /mm (after [43]). Time dependence of space charge accumulation at 0 and 180° phase angles of the supply voltage, different fields (55 and 20 kVrms/mm, 1 mHz, Figure 4A) and frequencies (1mHz and 0.1Hz, 55 kVrms/mm, Figure 4B).…”
Section: Model Feature Discussionmentioning
confidence: 99%
“…This is illustrated in Figures 3 and 4, after [43] where a thorough experimental comparison between the space charge accumulated under dc and ac voltage is reported. It is clear from these Figures that under ac voltage, even at quite low frequency and for long poling times, the residual charge is much smaller than under dc.…”
Section: The Ac Dmm Modelmentioning
confidence: 98%
“…This suggests that ac ageing results in the formation of deep traps for negative charge. It should be noted that in [10,12], space charges were measured while ac voltage was applied on the sample while in the present study the charges measured were those trapped in the sample after the removal of voltage. Therefore, the fast charge may be accountable for the difference in the results.…”
Section: Resultsmentioning
confidence: 73%
“…Indeed, it is only in the last five years or so that results, albeit limited, of space charge in polymeric insulation subjected to ac stress (herein known as ac space charge) have been reported [8][9][10][11][12].…”
Section: Introductionmentioning
confidence: 99%
See 1 more Smart Citation