2016
DOI: 10.1021/acs.analchem.6b01614
|View full text |Cite
|
Sign up to set email alerts
|

Abundance and Impact of Doubly Charged Polyatomic Argon Interferences in ICPMS Spectra

Abstract: Doubly charged molecular ions of alkaline earth metals and argon could be identified as spectral interferences in an inductively coupled plasma mass spectrometer. These molecular ions were found to occur at abundances reaching about 10(-4) relative to the alkaline earth atomic ion abundances. They can thus substantially affect ultratrace analyses and, when present at similar concentration as the analyte elements, also isotope ratio measurements. For the case of Cu and Zn isotope ratio analyses, the same mass c… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
5
0

Year Published

2016
2016
2024
2024

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 18 publications
(5 citation statements)
references
References 35 publications
0
5
0
Order By: Relevance
“…[31][32][33][34][35] It appears as an undesirable species in inductivelycoupled-plasma mass spectrometry and complicates the chemical analysis of S isotopes. 34,35 From the analysis of the density of MgAr 2+ at different plasma temperatures, Hattendorf et al could estimate the ground-state dissociation energy to be in the range between 124 and 130 kJ mol À1 . 34 In addition, Gardner et al 36 have characterized the electronic and vibrational structure of MgAr 2+ in high-level ab initio quantum-chemical calculations.…”
Section: Introductionmentioning
confidence: 99%
“…[31][32][33][34][35] It appears as an undesirable species in inductivelycoupled-plasma mass spectrometry and complicates the chemical analysis of S isotopes. 34,35 From the analysis of the density of MgAr 2+ at different plasma temperatures, Hattendorf et al could estimate the ground-state dissociation energy to be in the range between 124 and 130 kJ mol À1 . 34 In addition, Gardner et al 36 have characterized the electronic and vibrational structure of MgAr 2+ in high-level ab initio quantum-chemical calculations.…”
Section: Introductionmentioning
confidence: 99%
“…However, an increase in nebulizer flow rate also results in a shorter duration of the molecules/ions in the plasma, which leads to increased oxide formation, and decreased double charge formation. 24,25 This is reflected in an increased signal observed for all isotopes monitored, as a result of increased transport into the plasma with increasing nebulizer flow rate (Table S5†). Interference formation was also affected, with an increase in the fraction of oxides ( 160 Gd increases from 1.8 to 5.3%) and a decrease in the fraction of doubly charged ions ( 72 Ge decreases from 2.9 to 1.9%) measured as nebulizer gas flow rate increased from 0.7 to 0.86 L min −1 .…”
Section: Resultsmentioning
confidence: 96%
“…Doubly charged ions were found to depend significantly on the inductively coupled plasma operating conditions and generally increase with increasing carrier gas flow rates. They also increase by about an order of magnitude when a desolvated aerosol is introduced to the ICP [20].…”
Section: Icp-ms Analytical Techniquementioning
confidence: 99%