Purpose To assess the safety and efficacy of the StarClose SE Vascular Closure System (Abbott Vascular, Abbott Park IL, USA) in high-risk thrombocytopenic and coagulopathic interventional oncology (IO) patients. Methods In this single institution retrospective study, 63 high-risk thrombocytopenic or coagulopathic IO patients (M:F=51:12, mean age 58 years, range 31–88 years) who underwent 83 common femoral arteriotomy closures using the StarClose device were identified among all IO patients (n=131) undergoing StarClose closure (n=177) between 2008–2011. High-risk thrombocytopenia and coagulopathy were defined as platelet count ≤100 103/mL and international normalized ratio (INR) ≥1.5. Procedures included chemoembolization (n=67), radioembolization (n=8), and hepatic arterial mapping with technetium-99m macroaggrated albumin administration (n=8) for treatment of hepatocellular carcinoma (n=79) or liver metastases (n=4). Measured outcomes included technical success of arterial closure and closure-related adverse events, graded according to the Society of Interventional Radiology classification. Results In all cases, 5 French common femoral arterial access was used. Platelet count was ≤100 103/mL in 80/83 (96.4%) cases and INR was ≥1.5 in 35/83 (42.2%) cases. Mean pre-procedure platelet count was 71 (range 26–347) 103/mL and mean INR was 1.4 (range 1.0–2.1). The StarClose device effectively sealed the arteriotomy in 83/83 (100%) cases, 60/83 (72.3%) cases were first-time closures, and 20/83 (24.1%) cases were repeat closures. Small groin hematomas, graded as class A minor complications, developed in 3/83 (3.6%) cases. No other complications were encountered. Conclusions The StarClose SE Vascular Closure System confers high technical success and safety in common femoral arteriotomy closure in high-risk IO patients.
Purpose To assess the safety and efficacy of the StarClose SE Vascular Closure System (Abbott Vascular, Abbott Park IL, USA) in high-risk thrombocytopenic and coagulopathic interventional oncology (IO) patients. Methods In this single institution retrospective study, 63 high-risk thrombocytopenic or coagulopathic IO patients (M:F=51:12, mean age 58 years, range 31–88 years) who underwent 83 common femoral arteriotomy closures using the StarClose device were identified among all IO patients (n=131) undergoing StarClose closure (n=177) between 2008–2011. High-risk thrombocytopenia and coagulopathy were defined as platelet count ≤100 103/mL and international normalized ratio (INR) ≥1.5. Procedures included chemoembolization (n=67), radioembolization (n=8), and hepatic arterial mapping with technetium-99m macroaggrated albumin administration (n=8) for treatment of hepatocellular carcinoma (n=79) or liver metastases (n=4). Measured outcomes included technical success of arterial closure and closure-related adverse events, graded according to the Society of Interventional Radiology classification. Results In all cases, 5 French common femoral arterial access was used. Platelet count was ≤100 103/mL in 80/83 (96.4%) cases and INR was ≥1.5 in 35/83 (42.2%) cases. Mean pre-procedure platelet count was 71 (range 26–347) 103/mL and mean INR was 1.4 (range 1.0–2.1). The StarClose device effectively sealed the arteriotomy in 83/83 (100%) cases, 60/83 (72.3%) cases were first-time closures, and 20/83 (24.1%) cases were repeat closures. Small groin hematomas, graded as class A minor complications, developed in 3/83 (3.6%) cases. No other complications were encountered. Conclusions The StarClose SE Vascular Closure System confers high technical success and safety in common femoral arteriotomy closure in high-risk IO patients.
scite is a Brooklyn-based organization that helps researchers better discover and understand research articles through Smart Citations–citations that display the context of the citation and describe whether the article provides supporting or contrasting evidence. scite is used by students and researchers from around the world and is funded in part by the National Science Foundation and the National Institute on Drug Abuse of the National Institutes of Health.
hi@scite.ai
10624 S. Eastern Ave., Ste. A-614
Henderson, NV 89052, USA
Copyright © 2024 scite LLC. All rights reserved.
Made with 💙 for researchers
Part of the Research Solutions Family.