2017
DOI: 10.1016/j.ejmp.2017.09.045
|View full text |Cite
|
Sign up to set email alerts
|

Abstract ID: 87 Brachytherapy source and applicator models for diverse Monte Carlo simulations with egs_brachy

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
9
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
2

Relationship

0
2

Authors

Journals

citations
Cited by 2 publications
(9 citation statements)
references
References 5 publications
0
9
0
Order By: Relevance
“…The source model was previously benchmarked 28 . The direction cosines (extracted as described in the previous paragraph) were used to determine source orientation as described in Section 11.4 of the egs_brachy manual 36 . The “superposition” run mode with dwell position weights corresponding to normalized dwell times was used.…”
Section: Acquisition and Validation Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…The source model was previously benchmarked 28 . The direction cosines (extracted as described in the previous paragraph) were used to determine source orientation as described in Section 11.4 of the egs_brachy manual 36 . The “superposition” run mode with dwell position weights corresponding to normalized dwell times was used.…”
Section: Acquisition and Validation Methodsmentioning
confidence: 99%
“…28 The direction cosines (extracted as described in the previous paragraph) were used to determine source orientation as described in Section 11.4 of the egs_brachy manual. 36 The "superposition" run mode with dwell position weights corresponding to normalized dwell times was used. Although egs_brachy can account for the volume of a voxel occupied by the source in each dwell position and only score dose in the part of the voxel not occupied by the source using the "volume correction" option, this option was not used in the final simulations because better consistency with MCNP calculations was achieved with this option off (i.e., "correction type = none" in the "source volume correction" block).…”
Section: Monte Carlo Simulationsmentioning
confidence: 99%
“…10 Detailed descriptions of the egs_brachy MC code can be found in the study of Chamberland et al 10 and the egs_brachy user manual. 15 The egs_brachy MC application has also been benchmarked and validated against the extensively used BT MC code BrachyDOSE. 10,16,17 The Type B uncertainties of egs_brachy are recently compared to other state-of -the-art BT MC codes, PENELOPE-2018, and MCNP.…”
Section: Code Descriptionmentioning
confidence: 99%
“…This study also utilizes particle recycling; a variance reduction technique that reuses particles escaping from the source geometry an arbitrary number of times thus increasing the efficiency of the simulation. 15 Photons emitted from the source are recycled once, and each emitted photon is rotated by an arbitrary angle about the active length of the source (z-axis) prior to being recycled. Simulations that applied particle recycling are checked to ensure that the recycled particles do not result in nonindependent events and correlated data.…”
Section: Absorbed Dose Calculationmentioning
confidence: 99%
See 1 more Smart Citation