2012
DOI: 10.1080/00319104.2011.597029
|View full text |Cite
|
Sign up to set email alerts
|

Absorption and fluorescence spectral characteristics of norepinephrine, epinephrine, isoprenaline, methyl dopa, terbutaline and orciprenaline drugs

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1
1

Citation Types

2
10
0

Year Published

2012
2012
2022
2022

Publication Types

Select...
8

Relationship

1
7

Authors

Journals

citations
Cited by 26 publications
(12 citation statements)
references
References 33 publications
2
10
0
Order By: Relevance
“…The λ max red shift resulting from the tuning-scheme employed here has also been reported for other organic molecules, and this effect has been attributed to the larger amount of Hartree–Fock exchange in the default LC-RSH functional with respect to the tuned-RSH (recall that the obtained optimal ω parameter is ∼60% of the benchmarked value) . In terms of accuracy, the calculated absorption at 219 and 223 nm matches the measured spectrum of EPN in water by Siva et al (220 nm) . On the other hand, for the weakest excitation band, the maximum absorption wavelength of 265 nm is in better agreement with the experimentally measured band (280 nm) than with the default DFT hybrid; thus, a clear improvement of the simulated spectrum is aided by the gap-tuning scheme.…”
Section: Results and Discussionsupporting
confidence: 81%
See 1 more Smart Citation
“…The λ max red shift resulting from the tuning-scheme employed here has also been reported for other organic molecules, and this effect has been attributed to the larger amount of Hartree–Fock exchange in the default LC-RSH functional with respect to the tuned-RSH (recall that the obtained optimal ω parameter is ∼60% of the benchmarked value) . In terms of accuracy, the calculated absorption at 219 and 223 nm matches the measured spectrum of EPN in water by Siva et al (220 nm) . On the other hand, for the weakest excitation band, the maximum absorption wavelength of 265 nm is in better agreement with the experimentally measured band (280 nm) than with the default DFT hybrid; thus, a clear improvement of the simulated spectrum is aided by the gap-tuning scheme.…”
Section: Results and Discussionsupporting
confidence: 81%
“…39 In terms of accuracy, the calculated absorption at 219 and 223 nm matches the measured spectrum of EPN in water by Siva et al (220 nm). 84 On the other hand, for the weakest excitation band, the maximum absorption wavelength of 265 nm is in better agreement with the experimentally measured band (280 nm) than with the default DFT hybrid; thus, a clear improvement of the simulated spectrum is aided by the gaptuning scheme.…”
Section: Introductionsupporting
confidence: 57%
“…However, the pH of the eye drops could not be adjusted below 6.5 since that would irritate the eyes. In order to mitigate degradation, isoproterenol and propranolol drops were freshly prepared once per week in plastic vials and stored at 4 • C. UV spectra of the isoproterenol drops were measured over time to confirm drug stability (Siva et al, 2012).…”
Section: Eye Dropsmentioning
confidence: 99%
“…It has been well established that a wide range of organic molecules in aqueous solutions exhibit enhanced fluorescence when incorporated into CD hosts (9)(10)(11)(12)(13)(14)(15). If the guest molecule is a polarity-sensitive fluorescent probe, the complexation can be monitored by measuring the changes in the probe fluorescence upon addition of the CD host.…”
Section: Introductionmentioning
confidence: 99%