2018
DOI: 10.1002/mp.12777
|View full text |Cite
|
Sign up to set email alerts
|

Absorbed dose distributions from ophthalmic 106Ru/106Rh plaques measured in water with radiochromic film

Abstract: The proposed method may be useful to the users to perform quality assurance preclinical tests of Ru/ Rh plaques.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
3
1

Citation Types

0
4
0

Year Published

2018
2018
2024
2024

Publication Types

Select...
7

Relationship

1
6

Authors

Journals

citations
Cited by 8 publications
(4 citation statements)
references
References 38 publications
0
4
0
Order By: Relevance
“…The radiochromic film has replaced its predecessor, the radiographic film, as the film of choice for clinical radiology/radiotherapy applications since it eliminates the need for post‐processing and exhibits a wider dynamic range (up to hundreds of Gy). Therapeutic applications of radiochromic films include the patient‐specific Quality Assurance (QA), 1–4 linac commissioning, 5 brachytherapy QA, 6–10 treatment planning system (TPS) dose validation, 11 and so forth. The major advantage of radiochromic film over other dosimeters in brachytherapy applications is its high spatial resolution, customizability into any shape, and 2D measurement capability.…”
Section: Introductionmentioning
confidence: 99%
“…The radiochromic film has replaced its predecessor, the radiographic film, as the film of choice for clinical radiology/radiotherapy applications since it eliminates the need for post‐processing and exhibits a wider dynamic range (up to hundreds of Gy). Therapeutic applications of radiochromic films include the patient‐specific Quality Assurance (QA), 1–4 linac commissioning, 5 brachytherapy QA, 6–10 treatment planning system (TPS) dose validation, 11 and so forth. The major advantage of radiochromic film over other dosimeters in brachytherapy applications is its high spatial resolution, customizability into any shape, and 2D measurement capability.…”
Section: Introductionmentioning
confidence: 99%
“…We adopted the practical method described by Hermida-López et al [ 27 ] distributions in water produced by Ru ophthalmic applicators using EBT3 radiochromic films. A mold was made for each type of asymmetric plaque using dummy plaques and polymer clay.…”
Section: Methodsmentioning
confidence: 99%
“…27 Additional dosimetry studies have included the use of scintillation detectors, thermoluminescent dosimeters, semiconductor detectors, radiochromic films, diamond detectors, diode detectors, alanine pellets, alanine-polymer film, and ionization chambers. [28][29][30][31][32][33][34][35][36][37][38] For 106 Ru/ 106 Rh plaques, all current measurement techniques rely on the use of a calibrated device to perform relative dosimetry, as opposed to an extrapolation chamber where dose is determined directly as a primary measurement device.…”
Section: Introductionmentioning
confidence: 99%