Absolute radiometric calibration of the RapidEye multispectral imager using the reflectance-based vicarious calibration method

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
28
0

Year Published

2013
2013
2019
2019

Publication Types

Select...
8
1

Relationship

0
9

Authors

Journals

citations
Cited by 41 publications
(29 citation statements)
references
References 14 publications
0
28
0
Order By: Relevance
“…PlanetScope imagery is calibrated to a radiometric uncertainty across satellites of 5-6% at 1-sigma [44] and RapidEye is calibrated to 4% uncertainty [45]. These values compare reasonably to Landsat at-sensor calibration uncertainty, which ranges from 3% (OLI) to 5% (TM and ETM+) to 10% (MSS) [46][47][48].…”
Section: Limitations and Challengesmentioning
confidence: 98%
“…PlanetScope imagery is calibrated to a radiometric uncertainty across satellites of 5-6% at 1-sigma [44] and RapidEye is calibrated to 4% uncertainty [45]. These values compare reasonably to Landsat at-sensor calibration uncertainty, which ranges from 3% (OLI) to 5% (TM and ETM+) to 10% (MSS) [46][47][48].…”
Section: Limitations and Challengesmentioning
confidence: 98%
“…RapidEye is a five-satellite constellation launched on 29 August 2008, able to provide data on a daily basis at off-nadir conditions and every five days at-nadir [73]. Each satellite of the mission, named from RE1-RE5, carries identical MSI instruments.…”
Section: Overview Of Sensors and Satellite Datamentioning
confidence: 99%
“…The technical specifications of NAOMI-1 are reviewed in Table 1, and more details can be found in Mattar et al [9] and Aerial Photogrammetric Service (SAF) [10]. RapidEye is a five-satellite constellation launched on 29 August 2008, able to provide data on a daily basis at off-nadir conditions and every five days at-nadir [73]. Each satellite of the mission, named from RE1-RE5, carries identical MSI instruments.…”
Section: Overview Of Sensors and Satellite Datamentioning
confidence: 99%
“…This method is widely used to individually evaluate the radiometric function of satellites (Naughton et al 2011). In May and June 2015, a field campaign was performed in Goheung, South Korea, and Zuunmod, Mongolia, to calculate the absolute calibration coefficient using a reflectance-based vicarious method, which was calculated from the field campaign results and cross-calibration ( To evaluate the absolute calibration coefficient using a vicarious approach for KOMPSAT-3A, it was cross-validated with the Landsat-8 OLI sensor and TOA reflectance using the Libya-4 PICS.…”
Section: Mehtodmentioning
confidence: 99%