2008
DOI: 10.1063/1.2888110
|View full text |Cite
|
Sign up to set email alerts
|

Absolute polarimetry at RHIC

Abstract: Abstract. Precise and absolute beam polarization measurements are critical for the RHIC spin physics program. Because all experimental spin-dependent results are normalized by beam polarization, the normalization uncertainty contributes directly to final physics uncertainties. We aimed to perform the beam polarization measurement to an accuracy Of A&am/Pbeam < 5%.The absolute polarimeter consists of Polarized Atomic Hydrogen Gas Jet Target and left-right pairs of silicon strip detectors and was installed in th… Show more

Help me understand this report
View preprint versions

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
9
0

Year Published

2008
2008
2018
2018

Publication Types

Select...
4
3

Relationship

1
6

Authors

Journals

citations
Cited by 8 publications
(9 citation statements)
references
References 3 publications
0
9
0
Order By: Relevance
“…The BNL polarized atomic H jet [ 11 ] has an intensity of up to 1.7 10 17 atoms/s and polarization of ~0.97 in the DC mode of operation and it is possible to have an even higher intensity and polarization in the pulsed mode of operation. An ABS with very good parameters was developed for the internal target experiments at BINP [ 12 ].…”
Section: Proposed Modifications Of a Universal Abpismentioning
confidence: 99%
“…The BNL polarized atomic H jet [ 11 ] has an intensity of up to 1.7 10 17 atoms/s and polarization of ~0.97 in the DC mode of operation and it is possible to have an even higher intensity and polarization in the pulsed mode of operation. An ABS with very good parameters was developed for the internal target experiments at BINP [ 12 ].…”
Section: Proposed Modifications Of a Universal Abpismentioning
confidence: 99%
“…These developments can use to improve an ABPIS design. a b Figure 6: a) Schematic of the BNL ABPS [14]; the H-jet polarimeter includes three major parts: polarized Atomic Beam Source (ABS), scattering chamber, and Breit-Rabi polarimeter. The polarimeter axis is vertical and the recoil protons are detected in the horizontal plane.…”
Section: Pos(pstp 2013)050mentioning
confidence: 99%
“…A fourth system that is currently being developed is to use a camera to measure the fluorescence induced by the passage of the beam through a hydrogen jet [8], which is primarily used to measure and calibrate the beam polarization in RHIC [9]. At present, this system is limited to measuring just the vertical beam size.…”
Section: Introductionmentioning
confidence: 99%