2008
DOI: 10.1016/j.ijms.2007.09.019
|View full text |Cite
|
Sign up to set email alerts
|

Absolute measurements of isotope amount ratios on gases

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
14
0

Year Published

2008
2008
2020
2020

Publication Types

Select...
7
1

Relationship

1
7

Authors

Journals

citations
Cited by 18 publications
(14 citation statements)
references
References 14 publications
0
14
0
Order By: Relevance
“…In that prospect it was not the intention of this paper to search for new potential applications, but to explain in full detail the mathematical and physical backgrounds which underpin an 'absolute' isotope amount ratio measurement procedure. The basic theory is discussed while in a subsequent paper, illustrations by experimental values are described [24].…”
Section: Resultsmentioning
confidence: 99%
See 2 more Smart Citations
“…In that prospect it was not the intention of this paper to search for new potential applications, but to explain in full detail the mathematical and physical backgrounds which underpin an 'absolute' isotope amount ratio measurement procedure. The basic theory is discussed while in a subsequent paper, illustrations by experimental values are described [24].…”
Section: Resultsmentioning
confidence: 99%
“…Thus absolute isotope amount ratios can be obtained, achieving metrological traceability [23] to the derived SI unit mol/mol. This will be the subject of another paper [24].…”
Section: Gas Dynamics In the Mat271 Mass Spectrometermentioning
confidence: 90%
See 1 more Smart Citation
“…It was proven with numerous reports from IRMM researchers that mass discrimination effect during the effusion process in the gas/MS agrees well with the theoretical projection by gas kinetics. [22][23][24] The gas/MS used in this work (located at Korea Research Institute of Standards and Science, KRISS) shows the same characteristic with IRMM's instrument.…”
mentioning
confidence: 93%
“…33,34 Also, in the case of carbon dioxide, this approach has already been tested at the Institute for Reference Materials and Measurements (IRMM), Geel, Belgium, to calibrate a mass spectrometer with gravimetrically prepared mixtures. 17,[35][36][37][38][39][40][41] This publication presents a potential approach showing how the gravimetric mixture method can be adapted for carbon dioxide and how the isotopic equilibrium is considered in the calculation of the K-factors. The rst experiments testing our new approach, preparing binary mixtures from isotopically enriched parent materials, are presented.…”
Section: Introductionmentioning
confidence: 99%