2022
DOI: 10.3390/rs14112689
|View full text |Cite
|
Sign up to set email alerts
|

Absolute Frequency Readout of Cavity against Atomic Reference

Abstract: Future space-based geodesy missions such as the Mass Change Mission and the Next Generation Gravity Mission are expected to rely on laser ranging as their primary instrument. Short-term laser frequency stability has previously been achieved on the GRACE Follow On mission by stabilizing the lasers to an optical cavity. The development of a technique to provide long-term laser frequency stability is expected to be required. We have previously demonstrated a technique to track long-term frequency changes by using… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
2
0

Year Published

2022
2022
2023
2023

Publication Types

Select...
2
2
1

Relationship

0
5

Authors

Journals

citations
Cited by 5 publications
(4 citation statements)
references
References 20 publications
0
2
0
Order By: Relevance
“…The cavity resonance frequency and FSR are linearly related to each other through ν = n mode • FSR + offset, where the mode number n mode is an integer mode number. The offset must be calibrated on-ground [30]. The principle has been demonstrated in laboratory experiments with an accuracy of roughly 3 MHz ≈ 10 ppb.…”
Section: Discussion Of Results and Alternative Approaches For Future ...mentioning
confidence: 99%
See 1 more Smart Citation
“…The cavity resonance frequency and FSR are linearly related to each other through ν = n mode • FSR + offset, where the mode number n mode is an integer mode number. The offset must be calibrated on-ground [30]. The principle has been demonstrated in laboratory experiments with an accuracy of roughly 3 MHz ≈ 10 ppb.…”
Section: Discussion Of Results and Alternative Approaches For Future ...mentioning
confidence: 99%
“…The principle has been demonstrated in laboratory experiments with an accuracy of roughly 3 MHz ≈ 10 ppb. It is noteworthy that the scale factor tone and its sidebands have little influence on the conventional PDH readout [30,31]. The advantage of this technique is that only minor changes to existing flight hardware are needed, e.g., the use of GHz electro-optical modulators (EOMs) instead of MHz.…”
Section: Discussion Of Results and Alternative Approaches For Future ...mentioning
confidence: 99%
“…After determination of the USO frequency during precise orbit determination, this technique is able to provide an estimate for the FSR frequency with high accuracy. The principle has been demonstrated in laboratory experiments with an accuracy of roughly 3 MHz ≈ 1 ppb [30,31]. The advantage of this technique is that the changes in existing flight-hardware are only minor.…”
Section: Discussionmentioning
confidence: 98%
“…The longer timescales requirement could be met by minimally invasive measures to the experimental setup to further enhance the stability of these optical cavities. Applicable techniques are currently under investigation in the context of the next generation of Earth gravity field missions (Rees et al, 2021(Rees et al, , 2022.…”
Section: Primary Instrumentmentioning
confidence: 99%