2009
DOI: 10.1016/j.foodchem.2009.03.005
|View full text |Cite
|
Sign up to set email alerts
|

Absolute determination of soluble potassium in tea infusion by gamma-ray spectroscopy

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1
1

Citation Types

0
3
0
2

Year Published

2012
2012
2020
2020

Publication Types

Select...
5
3

Relationship

0
8

Authors

Journals

citations
Cited by 9 publications
(5 citation statements)
references
References 9 publications
0
3
0
2
Order By: Relevance
“…1524.6(3) 18.08(9) 312.60 (25) 0.336(20) 899.7 (4) 0.052(3) 1920.8 (10) 0.041(4) 1021.2 (9) 0.0201 (14) 2424.3 (7) 0.020(3) 692.0 (8) 0.0033 (7) 1228.0 (15) 0.0024 (11) Although most of these transitions can be seen in the gamma-ray spectra, as will be discussed in Sect. 2.5, only the transition with energy 1524.6 keV was used to measure the 42 K residual activity.…”
Section: Decay Scheme and Observed Radiationsmentioning
confidence: 99%
See 2 more Smart Citations
“…1524.6(3) 18.08(9) 312.60 (25) 0.336(20) 899.7 (4) 0.052(3) 1920.8 (10) 0.041(4) 1021.2 (9) 0.0201 (14) 2424.3 (7) 0.020(3) 692.0 (8) 0.0033 (7) 1228.0 (15) 0.0024 (11) Although most of these transitions can be seen in the gamma-ray spectra, as will be discussed in Sect. 2.5, only the transition with energy 1524.6 keV was used to measure the 42 K residual activity.…”
Section: Decay Scheme and Observed Radiationsmentioning
confidence: 99%
“…In the first step, calibrations using 152 Eu, 137 Cs and 60 Co standard reference pointsources considering sum effects were fitted by the least squares method [12,13]. Then, the efficiency ratio between extended-and point-source was determined by simulation, to account for the efficiency changes due both to varying distance and self-absorption, using a procedure developed in [14] and summarized below. We simulated photon energy deposition at the HPGe detector crystal with the MCNPX (Monte Carlo N-Particle eXtended) code [15] using Tally F : 8 (pulse height tally), setting the default electron and detailed photon physics parameters, and using the internal photo-atomic data libraries.…”
Section: Efficiency Calibrationsmentioning
confidence: 99%
See 1 more Smart Citation
“…São, porém, valores nominais dados pelo fabricante e podem não corresponder aos valores reais de cada detector. As discrepâncias entre os valores nominais e reais são devidas, principalmente ao processo de fabricação [111,112] e envelhecimento do detector [113]. Por esse motivoé necessário ajustar esses parâmetros para que a resposta do detector simulado correspondaà do real.…”
Section: Correção Da Eficiência No Detector Hpgeunclassified
“…• a simulação mostrou-se indispensável na quantificação do K no chá, ao avaliar a auto atenuação dos fótons em uma amostra de grande volume, dispensando a inconveniente construção de uma fonte radioativa específica para o experimento, que precisaria ser descartada após o uso [59];…”
Section: Desenvolvimento Da Pesquisa Ao Longo Do Tempounclassified