2021
DOI: 10.1107/s0108767321094721
|View full text |Cite
|
Sign up to set email alerts
|

Absolute configuration directly determined from 3D electron diffraction data

Abstract: Multiple scattering in 3D electron diffraction (3D ED) experiments is responsible for deviations of diffracted intensities from intensities expected from kinematical diffraction theory [1]. Though this is usually considered a disturbing factor in routine structure determinations, these deviations also contain valuable information on the absolute structure [2]. Analysing 3D ED measurements from different laboratories around the world, we demonstrate that the absolute structure of single submicrometric crystals … Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4

Citation Types

0
4
0

Year Published

2022
2022
2022
2022

Publication Types

Select...
1

Relationship

0
1

Authors

Journals

citations
Cited by 1 publication
(4 citation statements)
references
References 3 publications
0
4
0
Order By: Relevance
“…The data collection was automated by the in-house software, including the tracking of the crystal following the procedure described by Plana-Ruiz et al (2020). Continuous-rotation 3D ED data (cRED) reduction was performed using the computer program PETS2 (Palatinus et al, 2019;Klar et al, 2021). The specific data processing for cRED data used in the structure solution and the refinement is extensively detailed in Klar et al (2021).…”
Section: Crystallographic Datamentioning
confidence: 99%
See 3 more Smart Citations
“…The data collection was automated by the in-house software, including the tracking of the crystal following the procedure described by Plana-Ruiz et al (2020). Continuous-rotation 3D ED data (cRED) reduction was performed using the computer program PETS2 (Palatinus et al, 2019;Klar et al, 2021). The specific data processing for cRED data used in the structure solution and the refinement is extensively detailed in Klar et al (2021).…”
Section: Crystallographic Datamentioning
confidence: 99%
“…Continuous-rotation 3D ED data (cRED) reduction was performed using the computer program PETS2 (Palatinus et al, 2019;Klar et al, 2021). The specific data processing for cRED data used in the structure solution and the refinement is extensively detailed in Klar et al (2021). It includes the introduction of overlapping virtual frames (OVF) for the dynamical refinement that aims to model experimental intensities from continuous rotation data by summing consecutive experimental diffraction patterns into a set of virtual frames.…”
Section: Crystallographic Datamentioning
confidence: 99%
See 2 more Smart Citations