2014
DOI: 10.3390/rs6021327
|View full text |Cite
|
Sign up to set email alerts
|

Absolute Calibration of Optical Satellite Sensors Using Libya 4 Pseudo Invariant Calibration Site

Abstract: Abstract:The objective of this paper is to report the improvements in an empirical absolute calibration model developed at South Dakota State University using Libya 4 (+28.55°, +23.39°) pseudo invariant calibration site (PICS). The approach was based on use of the Terra MODIS as the radiometer to develop an absolute calibration model for the spectral channels covered by this instrument from visible to shortwave infrared. Earth Observing One (EO-1) Hyperion, with a spectral resolution of 10 nm, was used to exte… Show more

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

1
79
0

Year Published

2014
2014
2023
2023

Publication Types

Select...
7
1
1

Relationship

2
7

Authors

Journals

citations
Cited by 81 publications
(94 citation statements)
references
References 23 publications
1
79
0
Order By: Relevance
“…PICS-based calibration methods have been used by numerous researchers over an extended period of time [12,[14][15][16][17][18] A host of PICS sites have been endorsed by Committee on Earth Observation Satellites (CEOS) and these stable Earth-based sites have been used extensively to monitor the post-launch temporal stability of optical satellite sensors and for cross-calibration/inter-comparison purposes [12,[19][20][21][22][23]. In the cross-calibration method, the response of the sensor under investigation is compared against a reference sensor that is believed to be well calibrated over time [19,20,[24][25][26].…”
Section: Methods Overviewmentioning
confidence: 99%
“…PICS-based calibration methods have been used by numerous researchers over an extended period of time [12,[14][15][16][17][18] A host of PICS sites have been endorsed by Committee on Earth Observation Satellites (CEOS) and these stable Earth-based sites have been used extensively to monitor the post-launch temporal stability of optical satellite sensors and for cross-calibration/inter-comparison purposes [12,[19][20][21][22][23]. In the cross-calibration method, the response of the sensor under investigation is compared against a reference sensor that is believed to be well calibrated over time [19,20,[24][25][26].…”
Section: Methods Overviewmentioning
confidence: 99%
“…The PICS have been used for on-orbit radiometric trending of optical satellite for more than 15 years [14]. According to [15], the advantages of using these sites are their stable spectral characteristics over time, high reflectance, and minimal atmospheric effect on upward radiance. Several sites have been developed and include locations in Libya, Algeria, Niger and Mauritania.…”
Section: Cross-calibrationmentioning
confidence: 99%
“…According to [15], once spectral equivalency has been performed using the SBAF technique, for a stable atmosphere, the in-band reflectance can be directly compared to determine the differences between the sensors. Thus, the percentage differences were estimated between the well calibrated ETM+ and the at-sensor reflectance reported by the current calibration of MUX and WFI on-board CBERS-4 (see Equation (9)).…”
Section: Radiometric Coefficients Validationmentioning
confidence: 99%
“…More details on the PICSs can be found in Helder et al (2010). In the past these sites have been widely used in post launch calibration and validation of satellite sensors (e.g., Smith and Cox, 2013;Mishra et al, 2014;Sun et al, 2014;Uprety and Cao, 2015). Fortunately, in this area the impact of the ERS-2 tape recorder failure in June 2003 is quite small, so that the time series are almost complete with only a short gap in 2003.…”
mentioning
confidence: 99%