2023
DOI: 10.1016/j.zemedi.2023.01.003
|View full text |Cite
|
Sign up to set email alerts
|

Aberration correction in diagnostic ultrasound: A review of the prior field and current directions

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
2
1
1

Citation Types

0
6
0

Year Published

2023
2023
2024
2024

Publication Types

Select...
7
1

Relationship

0
8

Authors

Journals

citations
Cited by 17 publications
(10 citation statements)
references
References 159 publications
0
6
0
Order By: Relevance
“…Aberrators #1 and #2 had root mean square (RMS) values of 39 and 97, respectively. The full width at half maximum (FWHM) 35 of the autocorrelation function was estimated to be 1.14 mm for aberrator #1 and 0.96 mm for aberrator #2. In comparison, aberrator #2 was slightly stronger than what would typically be observed in vivo.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Aberrators #1 and #2 had root mean square (RMS) values of 39 and 97, respectively. The full width at half maximum (FWHM) 35 of the autocorrelation function was estimated to be 1.14 mm for aberrator #1 and 0.96 mm for aberrator #2. In comparison, aberrator #2 was slightly stronger than what would typically be observed in vivo.…”
Section: Methodsmentioning
confidence: 99%
“…C) FWHM 35 FWHMbadbreak=lim1lim2φφ0dφ.$$\begin{equation}FWHM = \int\limits_{{{{\lim }}_1}}^{{{{\lim }}_2}}{{\left( {\varphi - {\varphi }_0} \right)d\varphi }}.\end{equation}$$where lim1$li{m}_1$ and lim2$li{m}_2$ represent the angular positions of the echo signal distribution when it reaches half of its maximum value on both the left and right sides of the peak value.…”
Section: Methodsmentioning
confidence: 99%
“…[19][20][21] Similarly to the estimation of SoS, Aberration Correction has received much attention for more than 50 years and numerous algorithms have been proposed some with significant success. An excellent review of this topic is in this referenced article from R. Ali et al 22) Nonetheless, no commercial scanners with aberration correction capability have been reported until 2023 with the introduction of that feature in a GE Vingmed scanner. It will be of great interest to see the form and performance of future enhancements.…”
Section: Selected Sbf Topics Of Interestmentioning
confidence: 99%
“…Numerous techniques and models have been proposed to mitigate the image degradation that is caused by acoustic aberration [ 4 , 5 , 6 , 7 , 8 , 9 ]. A typical example is the near-field phase screen model, which simplifies the effect of acoustic aberration caused by uneven SoS distribution as a phase screen located in front of the ultrasound transducer [ 6 ].…”
Section: Introductionmentioning
confidence: 99%