2006
DOI: 10.1097/01.ijg.0000196653.77836.af
|View full text |Cite
|
Sign up to set email alerts
|

Ab Interno Trabeculectomy: Development of a Novel Device (Trabectome???) and Surgery for Open-Angle Glaucoma

Abstract: The Trabectome system is designed for performing trabeculectomy via an ab interno approach. It successfully removed sections of trabecular meshwork and Schlemm's canal inner wall with less injury to the adjacent tissue compared with goniotomy knife in vitro. Theoretically, this procedure should provide direct access of aqueous humor to Schlemm's canal.

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
4

Citation Types

0
75
0
5

Year Published

2007
2007
2022
2022

Publication Types

Select...
7
1
1

Relationship

0
9

Authors

Journals

citations
Cited by 134 publications
(80 citation statements)
references
References 17 publications
0
75
0
5
Order By: Relevance
“…Since 2006, the Trabectome®, a device used to perform an ab interno trabeculectomy, has been used in glaucoma surgery [12,13]. The trabecular meshwork is removed by electroablation, resulting in an increased aqueous outflow to the opened Schlemm's canal.…”
Section: Introductionmentioning
confidence: 99%
“…Since 2006, the Trabectome®, a device used to perform an ab interno trabeculectomy, has been used in glaucoma surgery [12,13]. The trabecular meshwork is removed by electroablation, resulting in an increased aqueous outflow to the opened Schlemm's canal.…”
Section: Introductionmentioning
confidence: 99%
“…Developed by Neomedix (Tustin, CA, USA) more than a decade ago [9], the Trabectome ablates 60-120 degrees of TM and the inner wall of Schlemm's canal by high-frequency electrosurgery [17]. The Trabectome provides active irrigation and aspiration, which maintains better stability and temperature in the anterior chamber, compared with passive chamber management [18].…”
Section: Introductionmentioning
confidence: 99%
“…These procedures reduce IOP by different mechanisms: 1) ablate or bypass the trabecular meshwork (TM) using instruments such as the Trabectome (Neomedix Corporation, Tustin, CA, USA) [9][10][11], iStent (Glaukos Corp., Laguna Hills, CA, USA) [12], or the Hydrus mini-stent (Ivantis Inc., Irvine, CA, USA) [13]; 2) establish a new route for suprachoroidal drainage (CyPass Micro-Stent; Transcend Medical, Menlo Park, CA, USA [14]; 3) reduce the production of aqueous humor [15]; or 4) create a subconjunctival filtration route [16].…”
Section: Introductionmentioning
confidence: 99%
“…The management strategies for HP include early initiation of aqueous suppressant treatment after AGV implantation [16] , steroid injection at the time surgery [17] , antimetabolites, digital massage [18] , bleb needling, and surgical excision of the bleb [8] . While GDDs bypass the conventional outflow, the Trabectome surgical system (NeoMedix, Tustin, CA, USA) enhances the conventional outflow [19] . It has a long track record of safety and efficacy in different types and severity of glaucoma [20,21] .…”
Section: Introductionmentioning
confidence: 99%