2020
DOI: 10.1007/978-1-0716-0966-8_17
|View full text |Cite
|
Sign up to set email alerts
|

Ab Initio Determination of Peptide Structures by MicroED

Help me understand this report

Search citation statements

Order By: Relevance

Paper Sections

Select...
1
1
1

Citation Types

0
3
0

Year Published

2021
2021
2023
2023

Publication Types

Select...
3

Relationship

1
2

Authors

Journals

citations
Cited by 3 publications
(3 citation statements)
references
References 37 publications
0
3
0
Order By: Relevance
“…Cryogenic temperatures also delay the onset and progression of radiation damage, which is frequently quite severe for macromolecular crystals at RT. For proteins and oligopeptides, several step-by-step protocols detailing cryo-preservation procedures have been published. , A glow-discharged EM grid is first loaded with 2–3 μL of an aqueous suspension of protein crystals (usually immersed in mother liquor from a successful crystallization trial, such as the hanging drop in Figure C). Subsequently, the grid is blotted and rapidly plunged into a small reservoir (∼4 mL) of liquid ethane.…”
Section: Methodsmentioning
confidence: 99%
See 1 more Smart Citation
“…Cryogenic temperatures also delay the onset and progression of radiation damage, which is frequently quite severe for macromolecular crystals at RT. For proteins and oligopeptides, several step-by-step protocols detailing cryo-preservation procedures have been published. , A glow-discharged EM grid is first loaded with 2–3 μL of an aqueous suspension of protein crystals (usually immersed in mother liquor from a successful crystallization trial, such as the hanging drop in Figure C). Subsequently, the grid is blotted and rapidly plunged into a small reservoir (∼4 mL) of liquid ethane.…”
Section: Methodsmentioning
confidence: 99%
“…With minimal modification, well-established programs such as iMosflm, 108 DIALS, 109 and XDS 110 have all been successfully applied to continuousrotation 3D ED data reduction. Detailed tutorials (such as for DIALS 111 and XDS 65 ) easily comprehensible to any practicing X-ray crystallographer have subsequently appeared in the literature. Likewise, current processing pipelines for serial diffraction (such as crystFEL 112 ) have also been ported to ED data.…”
Section: Data Reductionmentioning
confidence: 99%
“…The MicroED sample preparation, data collection, and data processing pipeline for proteins as well as small molecules has been described previously ( Shi et al, 2016 ; Bu and Nannenga, 2021 ; de la Cruz, 2021 ; Martynowycz and Gonen, 2021 ; Zee et al, 2021 ). A MicroED structure elucidation workflow for natural products and specialized targeted metabolites has been optimized from previously published methods ( Figure 2 ).…”
Section: Microed Structure Analysis Workflowmentioning
confidence: 99%